4-3 SERVICE

Error Code

Description

Cause

Remedy

Left

Display

Right

Display

ERR

05--

Feedback signal of

motor lost

Tachometer feedback wiring

between Wirefeeder motor

and motor control PCB not

connected or motor is stalled.

Disconnect Wirefeeder

from Power Source. Check

wiring between Wirefeeder

motor Tachometer and

motor control PCB is

correctly connected.

Reconnect Wirefeeder to

Power Source and if ERR

05 appears again with the

next weld then contact

your Accredited CIGWELD

Service Provider to

investigate the fault.

ERR

06--

Output current of

Wirefeeder exceeds

allowed maximum

value limit

1. Current running through

Wirefeeder exceeds 650A for

4 minutes.

2. Welding current signal

from Power Source is too

high with respect the actual

weld current.

1. Turn OFF Wirefeeder

and allow it to cool for

10 minutes then reduce

voltage / wirespeed setting

to reduce welding current

below 650A@40%.
2. Contact your Accredited

CIGWELD Service Provider

to investigate the fault.

ERR

07--

Power Source

Arc Established

signal has not

been received

within 20 seconds

of commencing

welding

Power Source does not

provide an Arc Establish

signal.

Override the Arc

Established signal, refer

to Subsection 3.24 or

retrigger the wirefeeder.

ERR

08--

Main control PCB

settings save or read

error

Motor Control PCB Memory

IC read/write cycle limit has

been exceeded.

1. Turn Wirefeeder OFF

then ON and check to see if

settings can then be saved.
2. Contact your Accredited

CIGWELD Service Provider

to investigate the fault.

ERR

20--

Display PCB settings

save or read error

Display PCB Memory IC read/

write cycle limit has been

exceeded.

1. Turn Wirefeeder OFF

then ON and check to see if

settings can then be saved.
2. Contact your Accredited

CIGWELD Service Provider

to investigate the fault.

ERR

21--

Welder mode

undefined

Incorrect DIP switch setting.

Disconnect Wirefeeder

from Power Source then

check DIP switch setting

and set S3S4S5 DIP switch

as to Subsection 3.09.

ERR

22--

Wirefeeder mode

undefined

Incorrect DIP switch setting.

Disconnect Wirefeeder

from Power Source then

check DIP switch setting

and set S1S2 DIP switch as

to Subsection 3.09.

Table 4-1 Error Codes and Remedies