Transmig vaf4 – Tweco VAF4 Transmig User Manual
Page 39
Advertising

TRANSMIG VAF4
Manual 0-5231
3-21
INSTALLATION, OPERATION AND SETUP
5. Disconnect the welding cable from the Euro adaptor.
a. Loosen the screw from the Euro adaptor. Note that a heat source may be required to loosen the
screw locking compound on the thread.
b. Remove the welding cable.
6. Disconnect the Trigger Wires that connects Euro Adaptor on the Motor Control PCB.
7. Remove the Thumb Screw as shown in Figure 4 then use the 3mm Allen Key supplied to remove the M6
× 6 Set Screw in the wirefeed plate, and remove the Euro adaptor from the wirefeed plate. Keep the two
screws for future use.
Welding Cable
Gas Hose
Solenoid
Trigger Wires
Motor Control PCB
Trigger Wires
Art # A-11523
Screw for
Welding Cable
Figure 3-15 Removing Euro MIG Torch Adaptor