Transmig vaf4hd – Tweco VAF4HD Transmig User Manual

Page 10

Advertising
background image

TRANSMIG VAF4HD

GENERAL INFORMATION 1-4 Manual 0-5269

7. Keep protective cap in place over valve except when

cylinder is in use or connected for use.

8. Read and follow instructions on compressed

gas cylinders, associated equipment, and CGA

publication P-1 listed in Safety Standards.

WARNING

MOVING PARTS can cause injury.

Moving parts, such as fans, rotors, and belts can cut

fingers and hands and catch loose clothing.
1. Keep all doors, panels, covers, and guards closed

and securely in place.

2. Stop engine before installing or connecting unit.
3. Have only qualified people remove guards or covers

for maintenance and troubleshooting as necessary.

4. To prevent accidental starting during servicing,

disconnect negative (-) battery cable from battery.

5. Keep hands, hair, loose clothing, and tools away

from moving parts.

6. Reinstall panels or guards and close doors when

servicing is finished and before starting engine.

!

WARNING

This product, when used for welding or

cutting, produces fumes or gases which

contain chemicals know to the State of Cali-

fornia to cause birth defects and, in some

cases, cancer. (California Health & Safety

code Sec. 25249.5 et seq.)

NOTE

Considerations About Welding And The

Effects of Low Frequency Electric and Mag-

netic Fields

The following is a quotation from the General Con-

clusions Section of the U.S. Congress, Office of

Technology Assessment, Biological Effects of Power

Frequency Electric & Magnetic Fields - Background Pa-

per, OTA-BP-E-63 (Washington, DC: U.S. Government

Printing Office, May 1989): “...there is now a very large

volume of scientific findings based on experiments at

the cellular level and from studies with animals and

people which clearly establish that low frequency mag-

netic fields and interact with, and produce changes in,

biological systems. While most of this work is of very

high quality, the results are complex. Current scientific

understanding does not yet allow us to interpret the

evidence in a single coherent framework. Even more

frustrating, it does not yet allow us to draw definite

conclusions about questions of possible risk or to offer

clear science-based advice on strategies to minimize or

avoid potential risks.”
To reduce magnetic fields in the workplace, use the

following procedures.
1. Keep cables close together by twisting or taping

them.

2. Arrange cables to one side and away from the opera-

tor.

3. Do not coil or drape cable around the body.
4. Keep welding power source and cables as far away

from body as practical.

ABOUT PACEMAKERS:

The above procedures are among those

also normally recommended for pacemaker

wearers. Consult your doctor for complete

information.