4-11 SERVICE

FAULT

CAUSE

REMEDY

5 Power indicator is

ON, no wire feed but

gas flows from the

MIG Torch when the

torch trigger switch is

depressed.

A

B

C

Preflow is operating.

Electrode wire stuck in conduit

liner or contact tip (burn-back

jam).

Faulty motor control PCB.

A

B

C

Adjust preflow time setting. Refer

to Section 3.08.

Check for clogged / kinked MIG

Torch conduit liner or worn contract

tip. Replace faulty components.

Have an Accredited CIGWELD

Service Provider investigate the

fault.

6 Wire feeds when the

torch trigger switch

is depressed but arc

cannot be established.

A

B

C

Poor or no work lead contact.

Wirefeeder signal is not initiating

the power source which could

be caused by a loose 19 pin plug

connection.

A fault or overload condition has

occurred in pins A & B of the 19

pin interconnection lead control

cable and the P.T.C. protection has

activated.

A

B

C

Clean work clamp area and ensure

good electrical contact.

Tighten 19 pin plug connection,

repair or replace the 19 Pin control

cable.

Refer to Subsection 3.29 Protection

of Power Source Contactor

Output Control. (P.T.C.) or have

an Accredited CIGWELD Service

Provider investigate the fault.

7 Wirefeed motor

operates but wire does

not feed.

A

B

C

Pressure on feed rolls not

correctly adjusted.

Incorrect feed rolls used.

Worn feed roll.

A

B

C

Adjust pressure on feed rolls so

that it will be set to a minimum

pressure that will provide

satisfactory wire feed without

slippage.

Check that feed roll being used

matches the wire size and type

being used.

Replace feed roll.

8 Jerky wire feed

A

B

C

D

Worn or dirty contact tip.

Worn feed roll.

Excessive back tension from wire

reel hub.

Worn, kinked or dirty conduit liner.

A

B

C

D

Replace contact tip.

Replace feed roll.

Reduce brake tension on spool hub.

Clean or replace conduit liner.

9 No gas flow

A

B

C

D

Gas hose is cut.

Gas passage contains impurities.

Gas regulator turned off.

Empty Cylinder

A

B

C

D

Replace or repair.

Disconnect gas hose from the

rear of Wirefeeder then raise gas

pressure and blow out impurities.

Turn on Regulator and adjust to

correct pressure.

Replace cylinder.

10 Gas flow continues

after the torch trigger

switch has been

released.

A

B

Postflow is operating.

Gas valve has jammed open due

to impurities in the gas or the gas

line.

A

B

Adjust postflow time setting. Refer

to Subsection 3.08.

Have an Accredited CIGWELD

Service Provider repair or replace

gas valve.

11 Wire does not feed

when torch trigger is

depressed

Faulty trigger switch / lead.

Repair or replace Torch / trigger

lead.

12 Wire continues to feed

when torch trigger

released

A

B

Wirefeeder in 4T (LATCH) mode

Torch trigger leads shorted.

A

B

Change to 2T (NORMAL) mode.

Repair or replace Torch / trigger

lead.