08 advanced features mode, Advanced features mode -9, Transmig vaf4hd – Tweco VAF4HD Transmig User Manual

Page 27

Advertising
background image

TRANSMIG VAF4HD

Manual 0-5269

3-9

INSTALLATION, OPERATION AND SETUP

3.08 Advanced Features Mode

Enter Advanced Features Mode by pressing both the left knob and right knob at the same time for more than 1.2

seconds.

NOTE

In Advanced Features Mode the Trigger Mode Control Button, SCH 1-SCH 2 button is inactive.

Exit Advanced Features Mode by pressing both the left knob and right knob at the same time for more than 1.2

seconds to Save the Settings and exit advanced features mode. Note if there has been no user input for 30 seconds,

the VAF4HD will save settings and automatically exit advanced programming mode.

Advanced Feature

Left Display

Feature Description

Right Display

Parameter / Selection

Local / Remote

This is used to select local panel

control on the Wirefeeder, or remote

control from the 8 pin remote

control socket on the front of the

Wirefeeder

Default Local / Remote = Local

Local / Remote

If MIG Remote is selected but no remote control device is connected to the 8 pin

control socket then the wirefeed speed will be 1.3MPM (minimum wirespeed) and

the voltage will be 14V (minimum volts).

Pre Flow

This is used to provide gas to the

weld zone prior to the wire striking

an arc.

Default Pre Flow = 0.1 sec

0.0 – 5.0 seconds

Run In

(Creep wirefeed speed)

This is used to change Wirespeed to

a percentage of the value set by the

operator. It can improve arc starts

by controlling the wire speed at the

instant the wire touches the base

metal.

Default Run In = 70%

30 – 150% of

Wirefeeder Speed

Setting

For example if you have 12m/min set speed and have 50% selected for Run-in

Speed, the speed of the wire will be 6m/min until the arc is established. Once the

arc is established, the speed ramps up to the set speed at the rate set (12m/min)

with Ramp Time described below.