TRANSMIG VAF4HD

INSTALLATION, OPERATION AND SETUP

3-34

Manual 0-5269

!

WARNING

DO NOT WEAR GLOVES WHILE THREADING THE WIRE OR CHANGING THE WIRE SPOOL.

H. Lower the pressure levers and with the gun lead reasonably straight, feed the electrode wire through the gun.

Fit the appropriate contact tip, eg a 0.9mm tip for 0.9mm wire.

I Press the INCH button to feed the wire through the gun.

!

WARNING

If the Gun Trigger is used to feed wire through the gun, the electrode wire will be at welding voltage

potential whilst it is being fed through the wirefeeder system.

!

WARNING

Before connecting the work clamp to the work piece make sure the mains power supply is switched off.

NOTE

VAF4HD default setting is for Transmig 550i. Refer to Table 3-6 on Page 3-14 for settings for Transmig

350i & 450i.

Connection to Transmig 350i, 450i, 550i

Art # A-11780

Positive Welding

Terminal (+)

VAF4HD Wirefeeder

Tweco No. 4 MIG Torch

Work Lead

19 Pin Control Socket

Negative Welding Terminal (-)

Figure 3-33 Setup for Wirefeeder with MIG (GMAW) Welding