TRANSMIG VAF4HD

Manual 0-5269

3-11

INSTALLATION, OPERATION AND SETUP

Advanced Feature

Left Display

Feature Description

Right Display

Parameter / Selection

Crater Wirefeed Speed

(only if Crater mode is ON)

This sets the reduced wire speed

during crater operation in 4T at the

end of the weld.

Default Crater Wirefeed Speed =

70%

An example is if Preview Wirefeed

speed is set to 14MPM and crater

wirefeed speed is set to 70%

crater wirefeed speed will be

9.8MPM. Note minimum crater

wirefeed speed is determined by

minimum preview wirefeed speed of

wirefeeder.

0 – 100% of

Welding Wirefeed

Speed Setting

Spot Time

This is used to weld two thin plates

together by melting the top &

bottom plates together to form a

nugget between them. The weld time

is set by the Spot Time.

Default Spot Time = 2.0 sec

0.1 to 20.0 seconds

Stitch feature is not available in spot mode.

Stitch Mode

This is used to weld two or more

components by stitch or interval

weld together. The weld time is set

by the Stitch Time and the non weld

time is set by the Dwell Time (off

time).

Default Stitch Mode = Off

Stitch Mode ON /

OFF

Stitch is only available in 2T or 4T modes.

Stitch Time

(only if Stitch mode is ON)

This sets the “welding on” time in

Stitch mode.

Default Stitch Time = 2.0 sec

0.2 to 4.0 seconds

Dwell Time

(only if Stitch mode is ON)

This sets the “welding off” time in

Stitch mode.

Default Dwell Time = 0.5 sec

0.1 to 1.0 seconds