Transmig vaf4hd – Tweco VAF4HD Transmig User Manual

Page 32

Advertising
background image

TRANSMIG VAF4HD

INSTALLATION, OPERATION AND SETUP

3-14

Manual 0-5269

3.09 Wirefeeder Configuration for Different Power Sources

WARNING

There are dangerous voltage and power levels inside this product. Turn OFF wirefeeder and disconnect

from the power source before removing cover from wirefeeder.

The factory default setting for the wirefeeder is set for the Transmig 550i power source. If a different power source

is being used then the user will need to set the Display PCB DIP switch as to Table 3-6 according to the power

source being used.

Display PCB

Art # A-11257

DIP Switch

Figure 3-6 DIP Switch on Display PCB

S3S4S5

Vmin

Vmax

Vsetmin(J&K)

Vsetmax(J&K)

Welder

S3=Off(0), S4=Off(0), S5=Off(0)

14

50

3.182

11.364

Transmig 550i (default)

S3=On(1), S4=Off(0), S5=Off(0)

10

44

2.273

10

Transmig 500i

S3=Off(0), S4=On(1), S5=Off(0)

10

36

0

10

Transmig 400i (Refer to Section

3.24 to override Arc Establish

signal for this welder.)

S3=On(1), S4=On(1), S5=Off(0)

14

40

3.182

9.091

Transmig 350i & 450i

S3=Off(0), S4=Off(0), S5=On(1)

15

40

0

-4.8

MPM20/500 & MPM12/400

(Refer to Note)

S3=On(1), S4=Off(0), S5=On(1)

15

30

0

5.5

MPM8/270 & MPM8/255

S3=Off(0), S4=On(1), S5=On(1)

Spare

S3=On(1), S4=On(1), S5=On(1)

8

50

User Type Setting (The Service

Manual outlines how to set the

wirefeeder for other Power Sources.)

Table 3-6 Voltage Setting

NOTE

When S6=ON(1), calibration functions in Advanced Features Mode is enabled; when S6=OFF(0), cali-

bration functions are disabled.

NOTE

When S1=ON(1),S2=OFF(0), WFS Setting is applicable for Transmig VAF4HD and it ranges from 1.3

MPM to 16.8 MPM.

NOTE

An adaptor cable is required for connection to MPM20/500 or MPM12/400 Engine Drive Power Sources.