4-3 SERVICE

Error Code

Description

Cause

Remedy

Left

Display

Right

Display

ERR

05--

Feedback signal of

motor lost

Tachometer feedback wiring

between Wirefeeder motor

and motor control PCB not

connected or motor is stalled.

Disconnect Wirefeeder from Power

Source. Check wiring between

Wirefeeder motor Tachometer and

motor control PCB is correctly

connected. Reconnect Wirefeeder to

Power Source and if ERR 05 appears

again with the next weld then

contact your Accredited CIGWELD

Service Provider to investigate the

fault.

ERR

06--

Output current of

Wirefeeder exceeds

allowed maximum

value limit

1. Current running through

Wirefeeder exceeds 650A for 4

minutes.
2. Welding current signal from

Power Source is too high

with respect the actual weld

current.

1. Turn OFF Wirefeeder and allow it

to cool for 10 minutes then reduce

voltage / wirespeed setting to reduce

welding current below 650A@40%.
2. Contact your Accredited

CIGWELD Service Provider to

investigate the fault.

ERR

07--

Power Source Arc

Established signal

has not been received

within 20 seconds of

commencing welding

Power Source does not provide

an Arc Establish signal.

Override the Arc Established signal,

refer to Subsection 3.24 or retrigger

the wirefeeder.

ERR

08--

Main control PCB

settings save or read

error

Motor Control PCB Memory IC

read/write cycle limit has been

exceeded.

1. Turn Wirefeeder OFF then ON and

check to see if settings can then be

saved.
2. Contact your Accredited

CIGWELD Service Provider to

investigate the fault.

ERR

20--

Display PCB settings

save or read error

Display PCB Memory IC read/

write cycle limit has been

exceeded.

1. Turn Wirefeeder OFF then ON and

check to see if settings can then be

saved.
2. Contact your Accredited

CIGWELD Service Provider to

investigate the fault.

ERR

21--

Welder mode

undefined

Incorrect DIP switch setting.

Disconnect Wirefeeder from Power

Source then check DIP switch

setting and set S3S4S5 DIP switch

as to Subsection 3.09.

ERR

22--

Wirefeeder mode

undefined

Incorrect DIP switch setting.

Disconnect Wirefeeder from Power

Source then check DIP switch

setting and set S1S2 DIP switch as

to Subsection 3.09.

Table 4-1 Error Codes and Remedies

NOTE

Once cause of error has been corrected then the power to the Wirefeeder must be turned OFF then ON

to reset and clear Error Code from the display.

Please follow Subsection 4.08 for more information regarding troubleshooting.