TRANSMIG VAF4HD

INSTALLATION, OPERATION AND SETUP

3-2

Manual 0-5269

B. Assessment of Area

Before installing welding equipment, the user shall make

an assessment of potential electromagnetic problems

in the surrounding area. The following shall be taken

into account.
1. Other supply cables, control cables, signalling and

telephone cables; above, below and adjacent to the

welding equipment.

2. Radio and television transmitters and receivers.
3. Computer and other control equipment.
4. Safety critical equipment, e.g. guarding of industrial

equipment.

5. The health of people around, e.g. the use of pace-

makers and hearing aids.

6. Equipment used for calibration and measurement.
7. The time of day that welding or other activities are

to be carried out.

8. The immunity of other equipment in the environ-

ment: the user shall ensure that other equipment

being used in the environment is compatible: this

may require additional protection measures.

The size of the surrounding area to be considered will

depend on the structure of the building and other ac-

tivities that are taking place. The surrounding area may

extend beyond the boundaries of the premises.
C. Methods of Reducing Electromagnetic Emissions

1. Mains Supply
Welding equipment should be connected to the

mains supply according to the manufacturer’s rec-

ommendations. If interference occurs, it may be

necessary to take additional precautions such as

filtering of the mains supply. Consideration should

be given to shielding the supply cable of permanently

installed welding equipment in metallic conduit or

equivalent. Shielding should be electrically continu-

ous throughout its length. The shielding should be

connected to the Welding Power Source so that good

electrical contact is maintained between the conduit

and the Welding Power Source enclosure.

2. Maintenance of Welding Equipment
The welding equipment should be routinely main-

tained according to the manufacturer’s recommen-

dations. All access and service doors and covers

should be closed and properly fastened when the

welding equipment is in operation. The welding

equipment should not be modified in any way except

for those changes and adjustments covered in the

manufacturer’s instructions.

3. Welding Cables

The welding cables should be kept as short as pos-

sible and should be positioned close together but

never coiled and running at or close to the floor level.

4. Equipotential Bonding
Bonding of all metallic components in the welding

installation and adjacent to it should be considered.

However, metallic components bonded to the work

piece will increase the risk that the operator could

receive a shock by touching the metallic components

and the electrode at the same time. The operator

should be insulated from all such bonded metallic

components.

5. Earthing/grounding of the Work Piece
Where the work piece is not bonded to earth for

electrical safety, nor connected to earth because

of its size and position, e.g. ship’s hull or building

steelwork, a connection bonding the work piece to

earth may reduce emissions in some, but not all

instances. Care should be taken to prevent the earth-

ing of the work piece increasing the risk of injury

to users, or damage to other electrical equipment.

Where necessary, the connection of the work piece

to earth should be made by direct connection to

the work piece, but in some countries where direct

connection is not permitted, the bonding should be

achieved by suitable capacitance, selected according

to national regulations.

6. Screening and Shielding
Selective screening and shielding of other cables

and equipment in the surrounding area may allevi-

ate problems of interference. Screening the entire

welding installation may be considered for special

applications.

Advertising