Installation Instructions for Mortise Type Exit Device 8977/8978

Inside

Outside

Left Hand

Reverse Bevel

"LHRB"

Right Hand

Reverse Bevel

"RHRB"

IMPORTANT: BEFORE STARTING

• Check hand of door - this

device is not reversible

• Door should be fitted and hung

Verify box label for size of exit
device, function and hand

Step #1 - Exit Hardware & Door Prep

Prep door according to Exit installation instructions A6705 and appropriate templates
(metal door templates 4537 and 4538; wood door templates A7460 and A7461).

Step #2 - Install Outside Trim, Exit Chassis and Cylinder

A. Outside Trim

1. Slide mortise lock into door and securely fasten with (2) flat head screws

2. For exterior applications gasket (52-0263) should be used to seal

between “ET” escutcheon and outside door surface

3. Route “ET” harness through wire cutout and out other side of door

4. Place “ET” control on door with spindle inserted through mortise lock

Outside of door

(2) Flat

head

wood

screws

ET Spindle

ET Control

Wire
harness

Mortise lock

Connector

Centerline for
(2) 1/4 - 20 x 2-3/8''
flat head
machine
screws

ET gasket