Profile series v.g1 exit device, Mortise installation instructions (continued), Step #6 – rail assembly – SARGENT Profile Series v.G1.5 Exit Devices User Manual

Page 15: Step #5 – installation of inside escutcheon, Fig. 1 fig. 3 fig. 2

Advertising
background image

13

800-810-WIRE (9473) • www.sargentlock.com • A7757B

Profile Series v.G1 Exit Device

Copyright © 2006, 2008, Sargent Manufacturing Company

, an A

SSA ABL

O

Y

Group company

. All rights reserved.

Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

Mortise Installation Instructions (Continued)

1. Connect ground wire to terminal E3 (Fig. 1), keypad harness to controller (Fig. 2), and ET motor

harness to motor connector (Fig. 3).

2. Place extra wire inside door hole and/or outside escutcheon being careful not to pinch wires.

3. Connectors go on only one way, do not offset connector and be sure they are completely seated.

4. Insert #8-32 x 1-1/4" screws through inside escutcheon and thread into outside escutcheon.

Straighten escutcheons and tighten securely.

NOTE : For RF Technology versions (G1-TU, G1-TP, G1-TA) refer to Section 9 to install through bolt screws.

5. Install batteries and cover according to instructions on page 9.

Step #6 – Rail Assembly

Attach rail assembly according to Exit installation instructions A6705

1

2

3

4

5

6

7

8

9

0

*

#

Ground

wire

ET Motor

harness

Keypad

harness

Outside

of door

Inside

of door

For RF Technology
refer to Section 9.

Step #5 – Installation of Inside Escutcheon

Fig. 1

Fig. 3

Fig. 2