Step #3 – Attach Fire Stop Plate

Installation Instructions (Continued)

Outside

of door

1-1/2'' Dia.

7/8''

NOTE: Required for 12- Fire Rated doors only

1. Drill (2) 1/8" diameter holes if the door is not supplied with them

2. Secure fire stop plate to door with (2) #8 x 1/2" self tapping screws

Outside

of door

Wires & connector
go through fire
stop plate

Keypad ribbon
cable/connector

1

2

3

4

5

6

7

8

9

0

*

#

Step #4 – Installation of Outside Escutcheon

Insert connector and wires

1.

For exterior applications gasket (68-1400) should be
used to seal between escutcheon and outside door surface

2a. For 12- fire rated devices feed keypad ribbon cable/connector

from outside of door through gasket then fire stop plate

2b. For non-12- exit devices, feed keypad ribbon cable/connector

through gasket then conduit hole in door

3.

Place escutcheon against door surface

For exterior applications.
gasket (68-1400) should
be placed between the
escutcheon and door surface

-

+

-

+

-

+

-

+

+

-

+

-

Non Fire Rated Exterior Doors-
Install Weather Conduit
(P/N 52-2847) as shown below