Operational Check

Installation of the RF Technology Lock

1. For devices without cylinder go to step 4

2. For devices with cylinders, insert key into cylinder and rotate

3. The key will retract the latch, the key should rotate freely

4. Depress inside rail to retract latch

5. Enter 1234* to unlock outside lever handle and retract latch

6. If Prox only (G1-PA) or RF Technology with Prox (G1-TA)

- refer to keypad programming instructions (A7716)

1

2

3

4

5

6

7

8

9

0

*

#

Key/Cylinder, Code

Verification

8

9

The antenna board must be carefully moved to access the upper through-bolt screw. Care should be taken
to prevent damage to the antenna retaining tabs during this process.

Press the two tabs away from the antenna board and lift the board off the mounting posts. Insert the flat head
through-bolt and secure the escutcheon in place. After tightening the top through-bolt, replace the antenna board
by placing it on the mounting posts and pressing into the retaining tabs.

A. Installation of the top through-bolt screw:

To remove the battery keeper, a flat bladed screwdriver or similar tool must be used.

Insert the screwdriver into the slot at the top of the battery keeper, lift up and pull the top of the keeper
away from the batteries.

To install, insert the tabs on the bottom of the keeper into the battery compartment slots and press the
keeper tightly against batteries.

B. Removal procedure for the Battery Keeper:

Flathead through-bolt

Antenna
Board

Retaining
Tabs

Mounting
Posts

Controller
Assembly

Insert screwdriver
tip and lift up

Battery
Keeper

Tip out

Keeper tabs

The RF Technology Lock (G1-TU, G1-TA, G1-TP) is installed as described in sections 1-8 with the
following exceptions:

• Installation of the top through-bolt screw
• Removal process for the battery keeper