Profile series v.g1 exit device, Step #3 – attach fire stop plate, Mortise installation instructions (continued) – SARGENT Profile Series v.G1.5 Exit Devices User Manual

Page 14: Step #4 – installation of outside escutcheon

Advertising
background image

12

800-810-WIRE (9473) • www.sargentlock.com • A7757B

Profile Series v.G1 Exit Device

Copyright © 2006, 2008, Sargent Manufacturing Company

, an A

SSA ABL

O

Y

Group company

. All rights reserved.

Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

Step #3 – Attach Fire Stop Plate

C

L OF 1-1/2" Dia.

(2) Self tapping
screws #8 x 1/2"
long for wood &
metal doors

(2) 1/8" Dia.
holes required

Slot

1-1/2" Dia.

7/8"

1-1/2"

Fire stop
plate

NOTE: Fire stop plate
is required on all fire
rated doors only

NOTE: Required for 12- Fire Rated doors only

1. Drill (2) 1/8" diameter holes if the door is not supplied

with them

2. Secure fire stop plate to door with (2) #8 x 1/2" self

tapping screws

Mortise Installation Instructions (Continued)

A. Insert Wires and Connector

1. For exterior applications gasket (68-1400) should be used

to seal between escutcheon and outside door surface

2. For 12- fire rated devices feed keypad ribbon cable/connector

from outside of door through gasket then fire stop plate

3. For non-12- exit devices, feed connector and wires through

gasket then hole in door

4. Place escutcheon against door surface

Wires & Connector
go through fire
stop plate

Ground wire

Keypad ribbon
cable/connector

Step #4 – Installation of Outside Escutcheon

For exterior applications
gasket (68-1400) should be
placed between the
escutcheon and the
door surface

-

+

-

+

-

+

-

+

+

-

+

-

Non Fire Rated Exterior Doors-
Install Weather Conduit
(P/N 52-2847) as shown below