37. Wipe all the material off the flanges around the

meter doors, on the chute, and capture that material
in the calibration bag.

38. Accurately weigh the calibration bag plus material. If

you set a “tare” on the scale, the reading is the
sample net weight, so skip step 39.

39. Subtract the empty container weight to determine

the application rate for

1

10

hectare (or

1

10

acre).

40. Press the Stop softkey

on the monitor

and enter the sample net weight (SampleWeight).

The monitor responds with a Calibration Constant.

Push the Save softkey

to accept this

value.

Calibration Close-Out
41. Wipe the calibration door seals. Close the calibration

door(s).

42. Re-install any removed final Range gears.

43. Remove and store the calibration crank.

Servo Seeding Example (step 39)
Net Weight

Metric

U.S. customary

TotalWeight
for bag plus sample

23.26 kg

22.76 lbs.

BagWeight

1.52 kg

3.36 lbs.

SampleWeight

23.26 - 1.52
= 21.74 kg

22.76 - 3.36
= 19.4 lbs.

SampleWeight

TotalWeight

BagWeight

=