Troubleshooting – Great Plains NTA3007 Operator Manual User Manual

Page 120

Advertising
background image

166-371M

Table of Contents

Index

2012-07-02

116

NTA907 or NTA3007

Table of Contents

Index

Great Plains Manufacturing, Inc.

Troubleshooting

See also:
See “Down-Pressure Adjustment Indications” on page 102, and
Troubleshooting and Alarms” topic in the
DICKEY-john

®

Air Cart Control manual.

Problem

Causes

Solutions

No material flow
(all rows)

Contact drive not engaged - centre section
locks still in ROAD

Raise opener sub-frames. Move centre
frame locks from ROAD to FIELD.

Tire problems at contact drive

Check transport and contact tire sizes and
inflation (page 166).

Broken or removed chain(s) in drive system

Check chains against See “Chain Routing
(page 175).

Removed final rate Range gear(s); for
example, single hopper operation with
incorrect meter disabled

Re-install gear(s) per chart and calibration
for affected meter.

Variable rate gearbox set to zero, or too low

Re-set gearbox per calibration.

Empty hopper

Load material.

Meter in use clogged

Clean-out meter (page 124).

Rear meter in use, but front meter box (not in
use) is clogged.

Clean-out meter (page 124).

Fan speed too low

Check pulses-per-rev setting for fan in seed
monitor (page 174). Increase fan speed to
recommended range (page 98).

Fan running backward

Reverse fan circuit hoses at hitch.

No material flow
(multiple rows)

Primary seed hose blocked

Check seed hoses for kinks, congealed
materials at low spots, nests and pests.

Tower inlet or turret blocked

No material flow
(one or two rows)

Seed tube blocked at row

Inspect and clear seed tube.

Tower port blocked for affected row

Disassemble distribution ring and clear
blockage.

False alarm - seed tube sensor
disconnected or failed

Run monitor self-test. Swap sensor with a
working row to verify failure. Replace sensor.

Material is flowing, but
is not detected by seed
monitor

This is normal during the first few meters/feet
of planting, as it takes some time for material
to reach rows.

Lower openers 3 m (10 feet) before planting
is to begin. Monitor does not check for
blockage during first 5 seconds.

Lift switch mis-adjusted, failed or mis-wired.

Check, adjust or replace switch (page 99).

Seed monitor disconnected at hitch

Connect seed monitor.

Planting too little
(some rows)

Partial blockage in meter chamber, seed
hoses, towers, seed tubes

Treat as blockage. See “No material flow
(multiple rows)
” and “No material flow
(one or two rows)
” in this table.

Advertising
This manual is related to the following products: