Meter calibration, Seeding example, Calibration targets – Great Plains NTA3007 Operator Manual User Manual

Page 94: Fertilizer example, Dry fertilizer, Chart data based on, Density compensation adjustment factor, Chart rate after density adjustment, Calibration: common first steps

Advertising
background image

90

NTA907 or NTA3007

Table of Contents

Index

Great Plains Manufacturing, Inc.

166-371M

Table of Contents

Index

2012-07-02

Meter Calibration

The seed rate charts are based on cleaned untreated
seed of average size and test weight. Many factors affect
meter rates including foreign material, seed treatment,
seed size, field conditions, and test weight. The Dry
Fertilizer Rate chart is based on a representative
granular fertilizer.

Great Plains recommends calibrating for the exact
materials you intend to apply. Calibration determines two
very important settings for achieving accurate rates:

• The kilograms per hectare (or pounds per acre) of the

meter at the current variable rate gearbox setting for
your particular seed or fertilizer.

• The Calibration Constant for the monitor to accurately

report (or control) the planting rate of your particular
seed or dry fertilizer.

The seed monitor must be setup for the drill, and if a
variable rate kit is installed, there is additional setup for
that. See “Monitor Material Configuration” on page 86.

The seed monitor must also be correctly set up for the
material(s), or the calibration will not result in useful
monitor displays, and may cause incorrect application
rates if a variable rate kit is installed.

Calibration: Common First Steps

The calibration is different for manual (crank-adjusted)
and servo (variable rate kit) gearboxes. These first steps
are common to both gearbox types.

The right column contains an example for the following
steps.

1.

Raise drill (page 43): This prevents the contact drive
wheel from engaging the transport tire.

2.

Turn on the seed monitor.

3.

Determine the Range and gearbox settings from the
rate charts.

4.

If your material has a density that is significantly
different from that used to generate the chart, you
may want to adjust the density before choosing the
initial gearbox setting and Range.

5.

Set Range (page 88): Set the Final Drive Range
gears per the seed chart or dry fertilizer chart.

6.

Load material (page 65): Make sure there is enough
material in the hopper(s) for at least

1

10

hectare (or

1

10

acre) plus an extra 35 to 45 kg (75 to 100 lbs.).

Agricultural Chemical Hazards:
Obey manufacturer or grower recommendations for safety
equipment and protective gear when using treated seeds.

Seeding Example
Calibration Targets:
Metric

U.S. Customary

Crop:

Wheat

Wheat

Flutes:

2 Stars

2 Stars

Drill:

NTA907-6006

NTA3007-6006

Target Seed Rate:

200 kg/ha

178 lbs/ac

Chart Data:
Range:

High

High

Closest Chart Rate: 201.3 kg/ha

179.6 lbs/ac

Initial Variable Rate
Gearbox setting:

62

62

Initial Calibration
Constant:

79197

79197

Fertilizer Example

Metric

U.S. Customary

Drill:

NTA907-6006

NTA3007-6006

Material:

Dry Fertilizer

Dry Fertilizer

MaterialDensity:

0.82 kg/litre

51.3 lbs/cu-ft

TargetRate:

200 kg/ha

178 lbs/ac

Chart Data Based On:
ChartDensity:

0.96 kg/litre

60 lbs/cu-ft

Density Compensation Adjustment Factor:
Factor =

0.96

÷ 0.82,

or: 1.17

60

÷ 51.3,

or: 1.17

Adjusted Rate =

200

× 1.17,

or: 234 kg/ha

178 x 1.17
or: 208.2

Chart Rate After Density Adjustment:
Range:

High

High

Closest Chart Rate: 235.5 kg/ha

210.1 lbs/ac

Initial Variable Rate
Gearbox setting:

66

66

Initial Calibration
Constant:

90509

90509

Factor

ChartDensity

MaterialDensity

--------------------------------------

=

AdjustedRate

TargetRate

Factor

Ч

=

Advertising
This manual is related to the following products: