Monitor material configuration, Material configuration setup screen for seeds, Material configuration setup screen for fertilizer – Great Plains NTA3007 Operator Manual User Manual

Page 90

Advertising
background image

86

NTA907 or NTA3007

Table of Contents

Index

Great Plains Manufacturing, Inc.

166-371M

Table of Contents

Index

2012-07-02

Monitor Material Configuration

The DICKEY-john

®

IntelliAg

®

monitor reads meter shaft

speeds and can report kg/ha (or pounds/acre) planted.

In order to report accurately, the monitor requires several
inputs. Inputs that rarely change were entered during drill
setup. Inputs specific to particular materials (seed or
fertilizer) need to be entered when those materials are
first used, and when changed.

Material Configuration Setup Screen
for Seeds

Type” - This must be set to “Gran Seed Monitor” to
configure for seeds.

Density Units” - In metric mode this is always kg/litre.
If configured for “U.S.” mode (U.S. customary units), this
is pounds-per-bushel or pounds-per-cubic-foot.

Density” - This is the density of seed being planted.
Obtain this information from the material
container/supplier. If unknown, use the value specified in
the rate chart.

Total Number of Towers” - This is the number of
primary hoses coming off the rear meter box
(this is always 4 for NTA907 or NTA3007).

Calibration Constant” - This is the number listed in the
seed rate charts for the rate you are planting or the
number obtained from running the calibration routine for
your specific seed.

Material Configuration Setup Screen for
Fertilizer

Type” - This must be set to “Gran Fert Monitor” to
configure for fertilizer.

Density” - Enter the density of Fertilizer being applied,
in kilograms-per-litre (pounds-per-cubic-foot). Obtain this
information from the material container/supplier. If
unknown, use the value specified in the rate chart.

Total Number of Towers” - This is the number of
primary hoses coming off the rear meter box
(this is always 4 for NTA907 or NTA3007).

Calibration Constant” - This is the number listed in the
seed rate charts for the rate you are planting or the
number obtained from running the calibration routine for
your specific fertilizer.

See the DICKEY-john

®

Quick Start guide for

more detailed instructions.

25421

Note: Always enter Density Units before entering the

Density value. Changing the value of Density
Units
will alter the value of Density.

Advertising
This manual is related to the following products: