Charge and bleed brake system – Great Plains NTA3007 Operator Manual User Manual

Page 140

Advertising
background image

136

NTA907 or NTA3007

Table of Contents

Index

Great Plains Manufacturing, Inc.

166-371M

Table of Contents

Index

2012-07-02

Charge and Bleed Brake System

Refer to Figure 138
7.

Fill the reservoir

with brake fluid, grade:

DOT3 / SAE J1703, or
DOT4 / SAE J1704 / FMVSS 116, or
DOT5.1

System capacity: less than 1 litre

Machine Damage Risk:
Do not use brake fluid: DOT5 / SAE J1705

DOT5 and DOT5.1 are completely different fluids.
DOT5.1 is compatible with the braking system.
DOT5 is not.
If there is any chance of confusion in your shop, use
DOT3 or DOT4.

8.

Screw cap on master cylinder reservoir. Start at an
outside hub for step 9.

Refer to Figure 139
9.

Unscrew bleeder valve

above brake to open line.

10. Cycle brakes on tractor. Close valve near end of

brake pedal stroke to prevent air from entering at
valve. Check fluid level at reservoir. Top-off as
needed to keep full.

11. When fluid appears at valve, close valve.

12. Repeat step 9 through step 11 for the other outside

hub, then the inside hubs.

Refer to Figure 140
13. At brake line tee

, loosen centre port connection

just enough to allow air to escape when system is
pressurized, but not enough to allow air to enter.

14. Cycle tractor brakes until no air bubble appear at

connection. Tighten connection.

15. Top off master cylinder reservoir.

Figure 138

Brake Master Cylinder

29584

1

1

Figure 139

Brake Cylinder Bleeder Valve

29585

2

2

Figure 140

Brake Line Tee

29578

3

3

Advertising