Operating Instructions

This section covers general operating procedures.
Experience, machine familiarity, and the following
information will lead to efficient operation and good
working habits. Always operate farm machinery with
safety in mind.

Pre-Start Checklist

Perform the following steps before transporting the
NTA907 or NTA3007 drill to the field.

High Pressure Fluid Hazard:
Escaping fluid under pressure can have sufficient pressure to
penetrate the skin. Check all hydraulic lines and fittings before
applying pressure. Fluid escaping from a very small hole can
be almost invisible. Use paper or cardboard, not body parts,
and wear heavy gloves to check for suspected leaks. If an
accident occurs, seek immediate medical assistance from a
physician familiar with this type of injury.
❑ Review “Important Safety Information” on page 5.
❑ Lubricate as indicated at “Lubrication and

Scheduled Maintenance” on page 148.

❑ Check all tires for proper inflation. See “Tire

Inflation Chart” on page 166.

❑ Check all bolts, pins, and fasteners. Torque as

shown in “Torque Values Chart” on page 167.

❑ Check drill for worn or damaged parts. Repair or

replace parts before going to the field.

❑ Check hydraulic hoses, fittings, and cylinders for

leaks. Repair or replace before going to the field.

CFM Overview

The Control Function Module (CFM) is located below the
DICKEY-john

®

console terminal. The CFM controls a

bank of solenoid valves on the drill, in the
Fold/Tilt/Marker circuit.

On/Up opens the solenoid valve for the function.
Off/Down closes the solenoid valve for the function.

When MASTER is On, turn On only one function switch at a
time. To avoid unexpected movement of unintended drill
hydraulic components, no more than one of the Fold, Tilt or
Marker switches should ever be On at the same time.

Note: The CFM “MASTER” switch is the master for the

CFM only. It does not affect power to the monitor
terminal or other drill functions.

29382

Pre-Start Configuration

Figure 19

Control Function Module

29380

CFM Switch Operation

MASTER

Fold

Tilt

Marker

Off (down)

Off (down)

Off (down)

Off (down)

Hydraulic Circuit Operation

Lift

Fan,

Auger

Fold, Tilt,

Marker

Transport

Hooks

Neutral

Neutral

Neutral

Neutral