Install fan, Install fan mount weldment, Relocate fan from shipping bracket – Great Plains 3PYP Predelivery Manual User Manual

Page 33: Step 85)

Advertising
background image

Planter Assembly 29

07/19/2011

401-312Q

Install Fan

The seed fan needs to be relocated from a shipping
bracket on the mainframe to a seed cart weldment. The
fan hoses and sensor harness are pre-connected.

Install Fan Mount Weldment

Refer to Figure 51
85. Locate the fan mount weldment:

401-518H BRKT FAN SIDE MNT WLDMT

Position it as shown on the left side of the front face
of the mated left arm flange.

86. Secure the mount and flanges by removing and re-

installing four sets of:

803-021C NUT HEX 5/8-11 PLT
804-022C WASHER LOCK SPRING 5/8 PLT
802-057C HHCS 5/8-11X2 1/4 GR5.

FigureSpacer:

Relocate Fan from Shipping Bracket

Refer to Figure 52
87. Remove and save four sets of:

803-014C NUT HEX 3/8-16 PLT
804-013C WASHER LOCK SPRING 3/8 PLT
802-017C HHCS 3/8-16X1 GR5

Refer to Figure 51
88. Relocate the fan to the weldment

installed at

step 86. Orient the outlet to face right. Secure to
weldment with saved fasteners from step 87.

89. Remove the shipping bracket

, U-bolt, washers

and nuts from the mainframe. These parts are not
re-used.

FigureSpacer:

Figure 51

Attach Fan Mount Weldment

27427

14

26

46

36

14

36

46

26

FigureSpacer:

Figure 52

Fan Mounted for Shipping

29165

24

43

33

1

33

43

24

14

1

Advertising