Track Tractor Preferred Method of Tractor Steering

Sensor Calibration

19. Turn the Ignition Switch to the ON position. DO NOT

START the ENGINE.

20. Put the Steer Toggle switch to the ON position. The

power light on the steering switch box and the LED’s
on the electronic steering module should all be illu-
minated.

21. Put the steering in the tractor sensor calibration

mode by setting Calibration switch

to the

TRACTOR position.

Note: Do not move the Calibration toggle switch from the

TRACTOR position until step 28 or the new tractor
calibration is ignored.

22. Turn the steering wheel all the way to the right and

hold in this position to simulate a hard right hand
turn.

23. Press and hold the LEARN button

on the switch

box until the LEARN indicator

flashes.

24. Release the steering wheel. It should return to the

center position.

25. Press and hold the LEARN button

on the switch

box until the LEARN indicator

flashes.

26. Turn the steering wheel all the way to the left and

hold in this position to simulate a hard left hand turn.

27. Press and hold the LEARN button

on the switch

box unti lthe LEARN indicator

flashes.

28. Complete the tractor sensor calibration mode by

setting Calibration switch

to OFF. Only at this

point are the new calibration values accepted by the
system.