CHAPTER

17

EXPORT ANALYSES

The VISCPRO

®

Export analyses (MRV Data Export and Error Data

Export) provide a convenient operator interface for configuring sample
or error information from the sample database for serial output and
exporting it in ASCII text format. The three port output filters (Date
Filter, Sample Filter/Error Page and Port Output Format) permit the
user to select and output desired data to a file, LPT port or serial port.

NOTE

Once the analysis has been exported, it cannot be reconfigured like other
VISCPRO

®

analyses. This prevents duplicate data from being resent to

network collection systems your lab may have in place. To re-send data,
close the analysis window (you may save the configured analysis if you
desire) and then recreate the analysis.

Analysis descriptions

The MRV Data Export analysis replicates the reporting options of the
CMRV Sample Data Table, making it possible to export any data
associated with sample tests. The Error Data Export analysis provides a
means of exporting error and instrument status information in a report
that may be useful for troubleshooting instrument performance.

Available data for analysis

In addition to exporting the selected data, the VISCPRO data export
analyses display it on the computer screen in a tabular format. The
following data is included in the MRV Data Export Analysis:

Sample ID—The ID for the test sample

Viscosity—Viscosity for the test sample

Yield—Yield Stress for the test sample

Profile—Temperature profile used for testing

Test Date—The date of the test

Test Time—The time of the test

Start Date—The starting date of the temperature profile

Start Time—The starting time of the temperature profile

Temp °C—The test temperature

Therm Temp—The reference thermometer temperature as input
into the VISCPRO software by the user prior to testing

Cell Num—The cell number associated with the test data

Data File—The time/temperature profile data file associated with
the test data

Instr Type—The instrument type associated with the test data

Instr ID—Instrument ID

Instr S/N—The serial number of the instrument associated with the
test data

Delay—Delay time before transmittal of serial data

ASCII Code—An ASCII character code input by the user, as defined
by its byte code

Smpl Type—the type of sample