CANNON

®

Mini-Rotary Viscometer

CMRV-5000 Instruction & Operation Manual

Version 1.0b—March, 2011; CANNON

®

Instrument Company

2139 High Tech Road • State College, PA • 16803 • USA

6

PREPARING FOR CMRV TESTING/CALIBRATION

27

Cleaning cycle .................................................................................................................... 27

Cleaning procedure ................................................................................................. 27
Inserting rotors ....................................................................................................... 30

7

CALIBRATING THE CMRV TEMPERATURE PROBE

31

Probe calibration procedure .................................................................................... 31
Manual restoration of voltage and offset data ........................................................... 33

8

CALIBRATING THE CMRV CELLS

35

Calibration theory ............................................................................................................... 35
Cell calibration procedure ................................................................................................... 36

Preparing the cells ................................................................................................... 36
Cell calibration test procedure ................................................................................. 38

9

USING THE CMRV SOFTWARE

41

VISCPRO

®

generic instrument interface .............................................................................. 41

Main options .......................................................................................................... 42
Security options ...................................................................................................... 44
Initial security setup ................................................................................................. 45
Print/Print setup options .......................................................................................... 46

Analyses options ................................................................................................................. 46

Analysis types ......................................................................................................... 46
Analyses menu options ............................................................................................ 47

Window options ................................................................................................................. 48
CMRV module menu options .............................................................................................. 49

Configure options ................................................................................................... 49
Print Instrument and Tray Settings ........................................................................... 49
Instrument Settings .................................................................................................. 49
Profile Designer ...................................................................................................... 50
View Cell Constants ............................................................................................... 50
Saving a configuration ............................................................................................. 51
Restoring instrument settings from a saved configuration ........................................... 51
Calibrate Cell Constants ......................................................................................... 52

Service menu options .......................................................................................................... 54