System a - 100, In- / outputs, Doepfer – Doepfer A-100(~ 40 MB) User Manual
Page 330

A-129 /3/4
Modular Vocoder
System A - 100
doepfer
6
4. In- / Outputs
!
CV In 1 ... CV In 5
Sockets ! are CV inputs. This is where you patch in
the voltages you would like to modify - ie, attenuate,
offset, or smooth out by slew limiting.
"
CV Out 1 ... CV Out 5
Sockets " are CV outputs, at which the modified
signals are available.
Each output signal is affected by a combination of
the attenuator, offset and slew limiter functions.
§
Slew Control Input
Socket § is the input for the CV generated by the
A-129 /4 Slew Limiter Controller.
This input should be connected with output & on the
A-129 /4.
This is a specialised control signal which must
come from the A-129 /4. Connecting signals from
other modules won’t make sense.
$
Freeze Control Input
A gate signal at input $ freezes the slew limiter’s
output signal (see Fig. 3).