System a - 100, A-150, Indicators – Doepfer A-100(~ 40 MB) User Manual
Page 469: Doepfer

doepfer
System A - 100
Dual VCS
A-150
3
3. Indicators
1
LED ... 2 LED
LEDs 1 and 2 serve as status indicators, to show
which of the two in / outputs " and § is at that moment
connected to the common out / input $.
4. In / Outputs
!
CV
Socket ! is the input for the digital control voltage,
whose level determines the switch state (see Fig. 1):
• CV low ( < ~3.6 V):
O/I ---- I/O 1
• CV high ( > ~3.6 V): O/I ---- I/O 2
If a high frequency control voltage is used for swit-
ching, audio frequency modulation results (see Fig. 4
on page 5).
Fig. 1: The A-150’s switching behaviour
"
I/O 1 • § I/O 2
These sockets are the in / outputs.
$
O/I
Socket $ is the common out / input. Depending on
the level of control voltage at input ! it’s connected to
socket " or § (see Fig.1).
CV
~ 3.6 V
O/I
I/O 1
I/O 2
O/I
I/O 1
I/O 2
O/I
I/O 1
I/O 2