5. In / Outputs
!
CV In • % CV In
Socket ! and % are the
inputs for the quantizers 1
and 2 respectively. The control voltage to be quantized
is patched into these sockets.
"
CV Out • & CV Out
At
outputs " and & the quantized voltages appear.
§
Trig. In • / Trig. In
If a trigger signal is applied to the
trigger input § or /
the quantization process takes place during
low/high
transition of the trigger signal. If this is not desired
leave the socket un-connected. Quantization then ta-
kes place at the internal rate of about 500Hz.
The external trigger signals are scanned with a rate of
about 1kHz. Therefore the external trigger frequency
has to be less than 500Hz to avoid aliasing effects. In
practice this will be no restriction as normal quantiza-
tion rates are much lower (usually only a few Hz).
fig. 6: External triggered quantization
1
12
V
Trig.
In
CV
Out
CV
In