Key lock function, Setting various functions, Basic settings and advanced settings – KEYENCE SK-1000 Series User Manual

Page 10: Key lock function 10, How to switch banks, Starting the key lock, Canceling the key lock (unlock), Setting screen, How to go to the setting screen, Basic operations on the setting screen

Advertising
background image

10

E SK-1000 IM

How to Switch Banks

Banks can be switched by either of the methods below.

Front panel commands on the amplifier.

Use the external inputs (Bank A input, Bank B input)*

* If the bank switching method is set to external input, and bank A input or bank

B input is set for the external input, banks can be switched with the external
input.

"10. External input" (page 15)
"11. Bank switching method" (page 16)

Key Lock Function

The key lock function prevents unwanted button operations during measurement.
When the key lock function is active, operations other than switching the main
screen and canceling the key lock function are disabled.

Starting the Key Lock

While pressing the [MODE] button on the main screen, press S or T button for 2
seconds or more.
After [Loc] blinks on the main display (upper level) for several seconds, the main
screen is restored.

If buttons other than display switching button on the sub display (lower level) are
operated in the key-locked state, [Loc] is displayed on the main display (upper
level) and setting change operation is ignored.

Canceling the Key Lock (Unlock)

While pressing the [MODE] button, press S or T button for 2 seconds or more.
After [

unL

] blinks on the sub display (lower level) for several seconds, the main

screen is restored.

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

Lock set

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

Lock canceled

4.

Setting Various Functions

This chapter describes the various functions of the SK Series.

Basic Settings and Advanced Settings

List of Setting Items

The following items can be set.

Setting Screen

This section describes operations and the setting screen to modify the basic
settings and the detailed setting.

„

How to go to the setting screen

Press the [MODE] button for approx. 2 seconds on the main screen.
The setting screen appears.

„

Basic operations on the setting screen

Changing the setting value: S / T button
Go to the next setting item: [MODE] button or X button
Return to the previous setting item: W button
Skip the rest of the settings and finish: Press and hold the [MODE] button for
approx. 2 seconds.

„

Setting screen view

The setting item is displayed on the main display (upper level) and the setting
value is displayed on the sub display (lower level).

Type

Setting item

Description

Reference

page

Basic
settings

1.Measurement range

Set the measurement range.

11

2.Averaging rate

Set the number of samples to average.

11

3.Output state

Select the output state (N.O./N.C.) of the
judgment output to turn ON/OFF
according to the judgment value.

11

Advanced
settings

4.Distance setting

Set the distance correction.

11

5. Area scaling

Set the area scaling.

12

6. Hold function

Set the method to use in holding the
judgment value (P.V.)

12

7.Timing input

Set the timing input type used for the
hold function.

14

8.Hysteresis

Set the hysteresis value for the tolerance
setting value.

14

9.Analog output scaling

Set the analog output scaling for the
judgment value (P.V.).

14

10.External input

Select the functions of the four external
inputs.

15

11.Bank switching method

Set the bank switching method.

16

12.Zero shift value memory

function

Set whether to store in the nonvolatile
memory (EEPROM) the state of the
display as shifted by the zero shift
function.

16

13. Display digit

Set the number of displayed digits of the
judgment value (P.V.) and the internal
measurement value (R.V.).

16

1. rnG

2. AvE

3. out

4. dst

5. HLd

6. HLd

7. tiM

8. HYS

9. AnG

10. in

11. bnK

12. SFt

13. dSP

Advertising