This chapter gives an overview of the SK Series as well as the name and function
of each part.

Checking the Package Contents

The following equipment and accessories are included in the package. Before
using the unit, make sure that all items are included.

Sensor Amplifier

„

DIN rail mount type

Sensor Head

List of Optional Parts

„

„

Sensor amplifier x 1
Instruction manual x 1

SK-1000 (main unit)

Sensor amplifier x 1

SK-1050 (expansion unit)

Sensor head x 1

SK-050

OP-26751 (for SK-1000/1050)

End unit x 2

OP-87056 (2 m)

OP-87057 (5 m)

OP-87058 (10 m)

OP87059 (20 m)

Sensor head connection cable
(M8 straight connector) x 1

OP-87660 (2 m)

OP-87661 (5 m)

OP-87662 (10 m)

OP87663 (20 m)

Sensor head connection cable
(M8 L-shaped connector) x 1

OP-84338

Sensor head
cable connector x 2

OP-87934

Ion balance monitor unit

Part Names and Functions

Sensor Amplifier Unit

„

SK-1000

*1 When shipped from the factory, a protective cover is installed over the

expansion slots.

*2 Not installed on the main unit.

„

Amplifier control unit

Item

Description

(1)

Main display

Displays the judgment value (P.V.) and each setting item.

(2)

HOLD indicator

Lights up when the judgment value (P.V.) is held.
"6. Hold Function" (page 12)

(3)

Judgment indicator

Displays whether the judgment value (P.V.) is HI (over the upper
limit), GO (within the acceptable range) or LO (below the lower
limit) against the tolerance setting value.
"Changing the Tolerance Values" (page 9)

(4)

Bank indicator

Displays a bank in use.
"Bank Function (Registering Multiple Tolerance Setting Values)"
(page 9)

(5)

Zero shift button

Press this button to match the internal measurement value (R.V.)
to zero.

(6)

Sub display indicator

Lights up according to the type of values displayed on the sub
display.

(7)

Sub display

Displays the internal measurement value (R.V.), temperature,
humidity, and each setting (selection) item.

(8)

Timing input indicator

Lights up while the timing input is ON when the timing input
(external input) is set to Level. Lights on approx. 0.5 sec. when
the timing input is set to Edge and the timing input is turned ON.

(9)

Zero shift indicator

The zero shift indicator will light up for approx. 0.5 second when
the zero shift function is used.

(10) SET button

Used to perform initializations.

(11) MODE button

Used when setting items, entering/exiting setting modes or
moving items.

(12) Arrow button

Used when selecting settings, changing display contents on the
sub display, etc.

(13) Alarm indicator

Lights up in the alarm state or error state.

(14)

kV display unit
indicator

Lights up when the judgment value (P.V.) display unit is kV.

(15)

V display unit
indicator

Lights up when the judgment value (P.V.) display unit is V.

HOLD

HI

V

kV

ALARM

BANK

SET

MODE

SELECT

ZERO SHIFT

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

SK-1000

Expansion unit connecto

r*1

Sensor head connector

Amplifier control unit cover

Expansion unit connector

*2

Amplifier control unit

HOLD

HI

V

kV

ALARM

BANK

SET

MODE

SELECT

ZERO SHIFT

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

SK-1000

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8) (9) (10)

(11)

(12)

(13)

(14)

(15)