Display screen and output, Factory setting (default value) list, E sk-1000 im – KEYENCE SK-1000 Series User Manual

Page 21

Advertising
background image

21

E SK-1000 IM

Display Screen and Output

Normally, the judgment value (P.V.) is displayed on the main display (upper level).
This section describes the judgment output and analog output status when
displays other than numbers appear on the main display.

Reference

The judgment indicator on the sensor amplifier operates in the same
way as Normally Open regardless of the output state setting.

Status

Amplifier

Control input

Control output

Analog

output

Upper

level

main

display

Judgment

indicator

Timing/

Reset

Bank

switching/

emission

stop

Zero-shift

Judgment

output

Alarm

Voltage

(current)

value

Measuring

Judgment
value
(P.V)

Measure-
ment
results

Yes

Yes

Yes

Measure-
ment
results

Output:
ON
Display:
OFF

Voltage
(current) for
measured
value

Out of
measurement
range

-----

All off

Yes

Yes

No

All OFF

Output:
OFF
Display:
ON

Analog
voltage
output: 5.5 V
fixed
Analog current
output: 3.0 mA
fixed

Out of display
range

FFFF

Only HI
lights

Yes

Yes

No

Only HI
output ON

Output:
ON
Display:
OFF

Upper limit of
analog output
range (For 1-5
V, fixed to 5 V)
(When upper
limit < lower
limit: 1 V)

Out of display
range

-FFFF

Only LO
lights

Yes

Yes

No

Only LO
output ON

Output:
ON
Display:
OFF

Lower limit of
analog output
range (For 1-5
V, fixed to 1 V)
(When upper
limit < lower
limit: 5 V)

Setting

Setting
item

Follows
setting
details

During
error:
No
Other
than
error:
Yes

Yes

Outside
measure-
ment
range,
during
error: No

Follows
setting
details

Output:
ON
Display:
OFF

Follows
setting details

Other than [Erc],
[ErE] errors

" Error

Displays and
Corrective
Actions" (page
20)

Error
display

HI/LO
simulta-
neously
light

No

Yes

No

HI/LO
output
simultane-
ously ON

Output:
OFF
Display:
ON

Analog
voltage
output: 5.5 V
fixed
Analog current
output: 3.0 mA
fixed

Overcurrent error

ErC

All off

Yes

Yes

Yes

All OFF

Measure-
ment in
progress,
or same as
out of mea-
surement
range

Voltage
(current) for
measured
value

EEPROM error

ErE

Measure-
ment
results

Yes

Yes

Yes

Measure-
ment
results

Measure-
ment in
progress,
or same as
out of mea-
surement
range

Voltage
(current) for
measured
value

-----

FFFF

-FFFF

ErC

ErE

Factory Setting (Default Value) List

This section describes the factory settings (default values).
If the initial reset is performed, the following default values will be restored.
" Initial Reset (Initialize)" (page 8)

Values set on the main screen
Banks 0 to 3 will all be set to the same values.

Basic settings and advanced settings

Setting item

Default value

HI tolerance setting value

1.000

LO tolerance setting value

-1.000

Setting item

Default

value

Description

1. Measurement range

near

Measurement can be performed in the range of 0
to ±2 kV and the reference distance for
measurement is 25 mm.

2. Averaging rate

64

Averaging rate: 64

3. Output state

no

Normally open

4. Distance setting

dEFLt

The distance will not be corrected.

5. Area scaling

1.00

1.00

6. Hold function

S-H

Sample hold.

7. Timing input

LEvEL

Level

8. Hysteresis

0.100

0.100

9. Analog output scaling

dEFLt

Default setting

10. External input

dEFLt

Default setting

11. Bank switching method

btn

Button operation

12. Zero shift value memory

function

M-oFF

Data will not be stored in the nonvolatile memory
(EEPROM).

13. Display digit

dEFLt

Default setting

Advertising