E SK-1000 IM

11. Bank switching method

Set whether to switch the bank with the amplifier buttons or with external inputs.

* If switching with buttons is selected, the bank can be switched only with the

amplifier buttons.
If switching with external input is selected, the bank can be switched only by
the external inputs.

„

Switching the bank with button operations

Press the S / T button while holding down the [MODE] button on the main
screen.
The bank will switch, and the bank indicator [BANK0 to 3] will light according to
the selected bank.

Reference

If the S button is pressed while holding down the [MODE] button,
the banks will change in the reverse direction.

The banks cannot be switched with buttons if the bank switching
method is set to external input. If the banks are switched with
buttons, the following is displayed.

„

Switching banks by external input

When the Bank A input and Bank B input are set for the external inputs, the bank
can be switched using the external inputs.

1

The banks are switched with the ON/OFF combination of the bank A
input and bank B input.

The bank input must be held 20 ms or longer.

The combinations of bank A input and bank B input are shown in the
following table.

Reference

If the external input is not set to bank A or bank B, it is regarded as
OFF.
(Example) If only Bank A input is set for the external input, only two

banks (bank 0 and bank 1) can be selected using the
external input.

2

The bank switching method must be set to external input.

Bank switching method

Description

Default

value

Switching with buttons

The banks are switched with the amplifier buttons.

c

Switching with external input

The banks are switched only by turning ON/OFF the
bank A input or bank B input set in "10. External
input"
.

Bank

Bank A input

Bank B input

Bank 0

OFF

OFF

Bank 1

ON

OFF

Bank 2

OFF

ON

ON: Short-circuited

Bank 3

ON

ON

OFF: Open

11. bnK

btn

in

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

Bank indicator

Bank indicator

Bank indicator

Bank indicator

<While bank 0 is
selected>

<While bank 1 is
selected>

<While bank 2 is
selected>

<While bank 3 is
selected>

BANK 0 lights

BANK 1 lights

BANK 2 lights

BANK 3 lights

Press T while holding

down the [MODE] button.

Press T while holding

down the [MODE] button.

Press T while holding

down the [MODE] button.

Press T while

holding down the

[MODE] button.

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

12. Zero shift value memory function

To save the zero shift performed with the external input, change the setting for the
nonvolatile memory (EEPROM) to save the shifted value.
When the zero shift is performed with the sensor amplifier button operation, it is
saved on the nonvolatile memory (EEPROM) regardless of the setting.

Point

If the data is written in the nonvolatile memory (EEPROM) over 1
million times, the error message is displayed and the setting may
not be saved any more. (It is still possible to obtain a
measurement value.)
For such cases as when a PLC frequently executes a zero shift,
and it is not necessary to store it in the nonvolatile memory
(EEPROM), it is recommended to turn this setting OFF.

13. Displayed digits

Set the number of digits for the judgment value (P.V.) and the internal
measurement value (R.V.) to display on the sensor amplifier.

Zero shift value memory

Description

Default

value

OFF

Do not save on the nonvolatile memory (EEPROM)

c

ON

Save on the nonvolatile memory (EEPROM)

Displayed digits

Description

Default

value

dEFLt

Operations are performed such as to maintain a
three-digit display. The unit is automatically
switched between V and kV and the decimal point
position is automatically switched.

c

0.001

3 decimal places

0.01

Truncate the 3rd decimal place

0.1

Truncate the 2nd decimal place

1

Truncate the 1st decimal place

12. SFt

13. dSP

Advertising