14

E SK-1000 IM

„

Auto absolute value hold

Until the hold-reset input is turned ON, the maximum absolute value of the

measured value is held as the judgment value (P.V.). External input is not

necessary.

7. Timing input

Set the external input (timing input) operation used for "6. Hold Function" (page

12).

If "Auto peak hold," "Auto bottom hold," or "Auto absolute value hold" is set, this
item is skipped.

For details, refer to the "6. Hold Function" (page 12).

8. Hysteresis

Set the hysteresis for the tolerance setting value.

If the judgment value (P.V.) fluctuates close to the tolerance setting value, causing

the judgment output to repeatedly turn ON and OFF, increase the hysteresis value

to stabilize the judgment output.

Reference

Above is the timing chart for when the judgment output state is

Normally Open (default value). ON/OFF is reversed for Normally Close.

9. Analog output scaling

The analog output scaling for the judgment value (P.V.) is set.

If the analog output is set to no output, this screen is skipped.

"Operation When the Power is Turned on for the First Time" (page 7)
"Initial Reset (Initialize)" (page 8)

Reference

If Upper limit = Lower limit is set, the analog output is as follows:

Judgment value (P.V.) < Upper limit: Analog output lower limit (1V in

the case of 1V to 5V output range)

Judgment value (P.V.) > Upper limit: Analog output upper limit (5V in

the case of 1V to 5V output range)

Item

Description

Default

value

Timing input

LeveL

(Level), edGe (Edge)

LEvEL

Item

Description

Default

value

Hysteresis

0.000 to 99.999

0.100

Analog output scaling

Description

Default

value

Default setting

Scaling is not performed.

c

Free range

Scaling is performed. The analog output range can
be changed by specifying the upper limit and lower
limit of the judgment value (P.V.).

Example 1: Lower limit < Upper limit

(Analog output 1 to 5 V)

Example 2: Lower limit > Upper limit

(Analog output 1 to 5 V)

Auto.A

Auto-absolute value-hold value

Measurement value

0

a

a

b

b

c

c

Display value

Time

Timing Input ON

OFF

Reset input

ON

OFF

7. tiM

8. HYS

Time

Hysteresis

Hysteresis

Judgment value (P.V.)

HI side setting value

LO side setting value

ON

OFF

ON

OFF

ON

OFF

HI judgment output

GO judgment output

LO judgment output

9. AnG

dEFLt

Free

Lower limit Upper limit

5

1

Output upper
limit

Output lower
limit

Judgment
value
(P.V.)

(V)

(V)

5

1

Lower limit Upper limit

Judgment
value
(P.V.)

Output upper
limit

Output lower
limit

z

Relation of voltage and analog output in default state (dEFLt)

The upper and lower limits for the different selections of analog outputs are as
follows.

„

Upper limit setting screen and lower limit setting screen

When set to the default state [dEFLt], the following screens will be skipped.
When set to free range, the upper limit setting and lower limit setting screens will
appear.

z

For free range (FrEE)

Press S / T button on each setting screen to specify the upper limit and the lower
limit.

z

Setting range for analog output scaling

If free range is selected for the analog output scaling state, the upper limit and
lower limit can be set within the range shown below.

Analog Output Accuracy

The analog output can be selected from ± 5 V, 1 to 5 V, 0 to 5 V or 4 to 20 mA.

*1 The averaging is as follows for averaging greater than 1024 times:

1024 times: Sampling rate x 4
2048 times: Sampling rate x 8
4096 times: Sampling rate x 16

Measurement range

Upper limit

Lower limit

NEAR

5.000

-5.000

FAR

50.000

-50.000

Analog setting

Output upper limit

Output lower limit

OFF

Not output

0-5v

5 V

0 V

-5-5v

5 V

-5 V

1-5v

5 V

1 V

AMPr

20 mA

4 mA

Measurement range

Description

Default value

Upper limit

-99.999 to 99.999

10.000

Lower limit

-99.999 to 99.999

-10.000

Voltage output

Current output

Output range

± 5 V
(Full scale 10 V)

4 to 20 mA
(Full scale 16 mA)

Output resistance

100 Ω

-

Maximum load resistance

-

350 Ω

Repeatability

± 1 mV

± 1.5 μA

Accuracy in respect to display ± 0.05% of F.S.

± 0.25% of F.S.

Temperature characteristics

± 0.005% of F.S./°C

± 0.01% of F.S./°C

Refresh rate

*1

Same as sensor head sampling rate

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

9. Analog Output

Scaling

Upper-limit setting

screen

Lower-limit setting

screen