Initial reset (initialize), Setting operations, E sk-1000 im – KEYENCE SK-1000 Series User Manual

Page 8: Buttons used, When buttons other than the, Mode] button, Analog output scaling" (page 14) button, Ampr

Advertising
background image

8

E SK-1000 IM

(5) LO side setting value screen

The lower limit of the acceptable range (tolerance setting value) for the target

is displayed. This setting value can be changed. If the judgment value (P.V.)

falls below the value set here, the LO judgment output turns on.

"Changing the Tolerance Values" (page 9)

(6) R.V. display screen

The internal measurement value (R.V.) is displayed. The displayed value is not

held even if a hold function is enabled.

Setting Operations

This section explains the functions of the main screen and the functions of each

setting screen.

„

Functions Operable on the Main Screen

„

Available Functions from the Main Screen

Main screen

Press W or X button.

Switching the sub display (lower level; page
7)

The internal measurement value (R.V.), HI

side setting value, LO side setting value,

temperature and humidity, temperature, or

humidity is displayed, and the settings can

be changed.

"Changing the Tolerance Values" (page 9)

Set the HI side tolerance setting value and

the LO side tolerance setting value. The value

is judged as HI, GO, or LO and is displayed

and output.

While pressing down [MODE], press S or T button.

"Bank Function (Registering Multiple
Tolerance Setting Values)" (page 9)

The HI side setting value, LO side setting

value, and shift target value can be saved in

up to four different banks, and the bank can

be switched.

Press [MODE] and S buttons for approx. 2 seconds.

or

Press [MODE] and S buttons for approx. 2 seconds.

"Key Lock Function" (page 10)

This function prevents unwanted button

operations during measurement.

Main screen

Press [MODE] button for approx. 2 seconds.

"Basic Settings and Advanced Settings"

(page 10)

Basic settings
Configure basic settings such as the

measurement mode and the averaging rate.

Advanced settings

Configure more advanced settings such as

the hold function and the timing input in order

to use the unit in a wider range of

applications.

While pressing the [MODE] button, press the

[SET] button 5 times.

"Initial Reset (Initialize)" (page 8)

All settings, excluding the calibration

function, are initialized.

[While pressing the [MODE] button, press the
W

button 5 times.

"Simulation Mode" (page 17)

You can use this function to check that the I/O

wires for control have been wired correctly.

HOLD

HI

V

kV

ALARM

BANK

SET

MODE

SELECT

ZERO SHIFT

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

SK-1000

Buttons used

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

Initial Reset (Initialize)

When an initial reset is performed, all settings, excluding the calibration function,
are initialized.
The judgment output's polarity and analog output setting can also be changed
through the same operation.

Reference

When buttons other than the

S

T

button and [MODE] button are

pressed during the initial reset procedure, the initial reset is
canceled and the screen in step 2 is restored.

When you attempt to initialize the unit while
the key lock function is set, the screen shown
on the right appears and the initialization fails.
Cancel the key lock before attempting to
initialize the unit.

"Key Lock Function" (page 10)

Main screen

1

While pressing the [MODE] button on the
main screen, press the [SET] button 5 times.

[reset] is displayed on the main display (upper
level).

While pressing

the [MODE]

button, press the

[SET] button 5

times.

2

Press S / T button to select [yes] and press
the [MODE] button

.

If [no] is selected at this point, only the output
polarity and analog output settings can be changed
without performing the initial reset.

[MODE] button

3

Press S / T button to select the output
polarity and press the [MODE] button.

[MODE] button

4

Press S / T button to select the analog
output and press the [MODE] button.
(For SK-1000 only)

"9. Analog output scaling" (page 14)

button

5

After the initialization is complete, [end] blinks
several times on the sub display and the main
screen is restored.

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

Performing the initial reset

PRP

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

QWV

GO

HOLD

CALC

CHECK

Output polarity

Setting value

Description

npn

NPN output

pnp

PNP output

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

Analog output

Setting value

Description

off

Not output

0-5u

Analog output after the judgment value (P.V.) is
converted to the range from 0 to 5 V.

-5-5u

Analog output after the judgment value (P.V.) is
converted to the range from -5 to 5 V.

1-5u

Analog output after the judgment value (P.V.) is
converted to the range from 1 to 5 V.

aMpr

Analog output after the judgment value (P.V.) is
converted to the range from 4 to 20 mA.

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO