2 setting and execution of a manual cycle – EVCO EVFTFT618N7U User Manual

Page 20

Advertising
background image

EVCO S.p.A.

EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224

Page

20

of

62

6.1.2 Setting and execution of a manual cycle

Below the complete navigation system of the MANUAL menu is illustrated.

From this menu it is possible to select and perform a complete manual COOLING or HEATING cycle.

To reach the MANUAL menu from the pre-selection page, press the key at the side of the MANUAL icon:

Press the START/STOP key to start the cycle. Press the START/STOP key for 3 seconds to interrupt the cycle.

Selecting the MANUAL menu allows to set a refrigeration (heating prohibited)

cycle or heating cycle with infinite duration

Pressing the UP/DOWN keys will change the e set-point to set. Pressing the +/- keys will

change the value of the set-point selected.

Pressing Home and Back are activated.

Pressing STAND-BY is deactivated

Pressing START starts the cycle

Manual Refrigeration/Heating screen

Main outputs

status bar

Pressing MENU slows to access

the options menu.

Refrigeration

List of AI, DI, AO, DO, SET values
for display (see dedicated

Manual Defrosting

REAL TIME DISPLAY

Heating

By pressing one of the 3 keys on the LEFT, select a Cooling cycle, pressing those

on the RIGHT, a Heating cycle.

Page for setting temperature set-point, humidity and fan speed. Humidity setting display
is subject to humidity control in the cycle requested. Speed setting visibility is subject to

management of the fan speed.

Access to the set-points

setting screen

Refrigeration

Heating

Advertising