5 management of the heating elements, 6 management of the steam generator, 7 humidification management – EVCO EVFTFT618N7U User Manual

Page 33: 1 cabinet step heating management, 2 management of humidity with transducer (ru0 = 0)

Advertising
background image

EVCO S.p.A.

EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224

Page

33

of

62

10.5 Management of the heating elements

During a heating request, the heating elements output will be activated, making the management of a switch-on/off duty-

cycle also possible, defined by parameters rH6 and rH7.

10.5.1 Cabinet step heating management

The desired set-point can be reached in the recovery and proving phases gradually, defining the number of steps to reach

the set-point and the percentage increase of the set-point for every step fixed.

For the recovery phase, the number of steps is defined by parameter rr0, while the percentage increases of the set-point

are given by parameters from rr1 to rr10.

For the proving phase, the number of steps is defined by parameter rL0, while the percentage increases of the set-point

are given by parameters from rrL1 to rL10.

Attention, it is the user's task to check the coherence of the number of steps set and the correct number of set-point

increase percentages. Example, if rr0 is equal to 4, only the parameters from rr1 to rr4 must be set.

10.6 Management of the steam generator

The steam generator output is active during all phases in which cabinet humidification management is envisioned.

10.7 Humidification management

The humidity in the cabinet can be managed with or without the use of humidity transducer, depending on the value of the

parameter rU0.

10.7.1 Management of humidity without transducer (rU0 = 1)

In this case, the humidifier output will remain active for a variable duty-cycle according to the humidity set-point set for

the phase in progress.

The duration of the activations and deactivations of the output is given by parameters rU2 (humidification cycle time) and

the maximum humidification time to obtain 100% humidity inside the cabinet (rU3).

The activation times will therefore be a percentage of the parameter rU3, on the basis of the set-point set, which will

repeat every cycle time set with rU2.

10.7.2 Management of humidity with transducer (rU0 = 0)

The humidifier output activates when the humidity value inside the cabinet drops below the neutral area value (rU9) of the

humidification differential value (rU8). The activation percentage of the humidifier output will be proportional to the value

of the humidity with respect to the humidification proportional band value (rU10), on the basis of the humidification cycle

time (rU11) and a times base for said time (rU12).

Advertising