Digital outputs (electromechanical relays; A res. @ 250 VAC)

compressor

16 A

cabinet light

8 A

humidifier

8 A

dehumidifier/condenser fan

8 A

defrosting

8 A

heating elements

16 A

steam generator

8 A

pump down valve/evaporator fan

8 A

Communication port

RS-48 serial port with MODBUS communication protocol

•

USB type serial port

•

Other features

IP65 protection rating of the user interface

IP65

clock

•

signal buzzer and alarm

•

management of temperature alarms

•

“programs” function

•

configuration parameters access password

•

restoring the factory settings

•

Notes:

(1) The evaporator fan control signal can be analogue or digital.

For further information, see chapter 0 15 TECHNICAL DATA; for other models contact the EVCO sales network.