EVCO EVFTFT618N7U User Manual

Page 37

Advertising
background image

EVCO S.p.A.

EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224

Page

37

of

62

Pr4

Humidity transducer error.

Solutions:

-

check the integrity of the transducer

-

check the device-transducer connection

-

check the humidity relative to the cabinet.

Main consequences if parameter rU0 is set at 0:

-

if the error occurs during “stand-by”, cycles that envision humidity management cannot be

launched

-

if the error occurs during the execution of a cycle that envisions humidity control, the cycle will

be interrupted.

rtc

Clock error.

Solutions:

-

set the real date and time again.

Main consequences:

-

the device will not be able to start automatic cycles

-

any automatic cycles in progress will be blocked.

ErC

User interface-control module compatibility.

Solutions:

-

check that the user interface and the control module are compatible.

Main consequences:

-

interruption of cycle in progress.

ErL

User interface-control module communication error.

Solutions:

-

check user interface-control module control module.

Main consequences:

-

interruption of cycle in progress

Advertising