A1

0

99

°C

70

evaporator temperature above which evaporator high

temperature alarm is activated (code “AH”); see also

parameter A2

A2

0

1

- - - -

1

enabling of evaporator high temperature alarm (“AH” code)

1 = yes

Par.

Min.

Max.

Unit

Default

Evaporator and condenser fan

F0

0

1

- - - -

0

evaporator fan activity during block phase

0 = operation in parallel with compressor

1 = continuous operation

F1

0

1

- - - -

0

evaporator fan activity during storage. cooling, pre-cooling

phase

0 = operation in parallel with compressor

1 = continuous operation

F2

0

1

- - - -

0

evaporator fan activity during recovery phase

0 = operation in parallel with main utilities

1 = continuous operation

F3

0

1

- - - -

0

evaporator fan activity during proving, heating phase

0 = operation in parallel with main utilities

1 = continuous operation

F4

0

1

- - - -

0

evaporator fan activity during baking delay phase

0 = operation in parallel with main utilities

1 = continuous operation

F10

0

100

%

100

fan speed in pre-cooling phase

F11

0

100

%

100

fan speed in dehumidification phase

F12

0

15

m

2

fan stop after dripping phase

F13

0

250

s

0

delayed switch-off of the evaporator fan from main utilities

off

F14

1

600

sec

0

evaporator fan cycle time, if set at 0, the cyclical switch-on

of the fan will be deactivated.

F15

1

600

sec

0

evaporator fan switch-on time within the cycle time F14

F16

0

99

°C

20

temperature of the condenser above which the condenser

fan is on also with compressor off

F17

0

240

s

5

condenser fan switch off delay on compressor switch off

(valid only with condenser probe disabled)

F18

0

240

s

15

evaporator fan switch-on delay from door closure, i.e. from

the deactivation of the door micro switch input

F19

0

100

%

20

minimum evaporator fan speed settable

F20

0

100

%

100

maximum evaporator fan speed settable

F21

0

100

%

75

evaporator fan top speed

F22

1

10

s

5

top speed at evaporator fan switch-on

Advertising