9 regulations, 1 pre-cooling, 2 temperature regulation – EVCO EVFTFT618N7U User Manual

Page 29: 1 generating cold

Advertising
background image

EVCO S.p.A.

EVFTFT618 | Installer manual ver. 2.2 | Code 144FTFT618E224

Page

29

of

62

9 Regulations

9.1

Pre-cooling

The pre-cooling cycle has the purpose of taking the cabinet to a determined temperature before selecting and performing

a retarder-proofer cycle.

During the pre-cooling cycle, the compressor, condenser fans, the pump-down electrovalve (if enabled) and the

evaporator fan work to reach the temperature established.

Once the pre-cooling temperature has been reached, the buzzer rings intermittently to indicate that the machine is ready

to perform a cycle. The buzzer is silenced by pressing any key or after the time defined by parameter E11.

The pre-cooling cycle continues until the START/STOP key is pressed or until an automatic or manual cycle is started by

the user.

9.2

Temperature regulation

The temperature regulation for all machine phases is with neutral area.

Meaning with a work set-point and a neutral area within which activations of loads set-up for heating or cooling do not

take place.

When the temperature goes above the neutral area value of the cooling differential value, the utilities set-up for cooling

will be activated until the temperature returns within the neutral area value.

In the same way, when the temperature goes below the neutral area value of the heating differential value, the utilities

set-up for heating will be activated until the temperature returns within the neutral area value.

9.2.1 Generating cold

The generation of the cold refers to the cooling circuit installed on the machine.

During a cooling request, the compressor output will be activated along with the pump-down electro valve (if enabled).

The evaporator fan will go in continuous mode or parallel to the compressor on the basis of that established for each

parameters configuration phase and at the speed established for the phase in progress.

Cooling differential

Cooling neutral area

Heating neutral area

Heating differential

cold

hot

(depending on the phase)

(depending on the phase)

Advertising