EVCO EC6708 User Manual

Page 26

Advertising
background image

Every Control S.r.l.
Via Mezzaterra 6, 32036 Sedico Belluno ITALY • Phone 0039-0437-852468 (a.r.) • Fax 0039-0437-83648 • [email protected] • www.everycontrol.it

26

the first parameter of the second level).

To select a parameter of the second level:

j) repeat the passage c as long as the instrument displays the

label of the desired parameter, for instance Po 1.

To modify the parameter value:

k) push and release the set key (to the release of the set key the

instrument displays the actual value, for instance 10 and the
set LED flashes to indicate that a configuration parameter
modification procedure is running; passed four seconds with-
out operated with the keys the instrument automatically turns
out from the configuration parameter modification procedure)

l)

push and release over and over the up or the down key within
four seconds as long as the instrument displays the desired
value, for instance 15 (keeping pushed the up or the down key
the value gets increased or decreased more quickly)

m) after the modification push and release the set key (to the

release of the set key the instrument displays the label Po 1
again.

To turn out from the Configurator Menu configuration parameters
setting procedure:

n) keep pushed for two seconds at least the menu key or the ON

STAND-BY key (passed two seconds the display and the LED
turning off, except the ON STAND-BY LED) or ...

n’) ... or do not operate with the keys for sixty seconds at least

(passed sixty seconds the display and the LED turning off, ex-
cept the ON STAND-BY LED).

Additional informations
• during a corrupted memory data alarm the access to the

Configurator Menu configuration parameters setting proce-
dure is refused (see the paragraph Alarms on the page 46)

• the parameters value gets stored in a non volatile memory

even if a lack of power supply happens.

CONFIGURATOR MENU CONFIGURATION PARAMETERS
To make easy the configuration parameters consultation of this Menu,
we have provided to divided it in families.

LABEL MIN.

MAX.

U.M.

USERS TOTAL WORKING HOURS
COUNTER

Hr 1

----

----

hour

total working hours of the user asso-
ciated to the output K1 (1)

Hr 2

----

----

hour

total working hours of the user asso-
ciated to the output K2 (1)

Hr 3

----

----

hour

total working hours of the user asso-
ciated to the output K3 (1)

Hr 4

----

----

hour

total working hours of the user asso-
ciated to the output K4 (1)

Hr 5

----

----

hour

total working hours of the user asso-
ciated to the output K5 (1)

Hr 6

----

----

hour

total working hours of the user asso-
ciated to the output K6 (1)

Hr 7

----

----

hour

total working hours of the user asso-

CONFIGURATOR MENU