LABEL MIN.

MAX.

U.M.

DEF.

USERS TOTAL WORKING HOURS COUNTER

Hr 1

----

----

hour

----

total working hours of the user associated to the output K1 (1)

Hr 2

----

----

hour

----

total working hours of the user associated to the output K2 (1)

Hr 3

----

----

hour

----

total working hours of the user associated to the output K3 (1)

Hr 4

----

----

hour

----

total working hours of the user associated to the output K4 (1)

Hr 5

----

----

hour

----

total working hours of the user associated to the output K5 (1)

Hr 6

----

----

hour

----

total working hours of the user associated to the output K6 (1)

Hr 7

----

----

hour

----

total working hours of the user associated to the output K7 (1)

Hr 8

----

----

hour

----

total working hours of the user associated to the output K8 (1)

LABEL MIN.

MAX.

U.M.

DEF.

OPERATOR MENU PASSWORD

OPEr

-999

9999

----

0

Operator Menu password (2)

LABEL MIN.

MAX.

U.M.

DEF.

COMPRESSORS POWER MANAGER

Po 1

1

15

----

10

power of the compressor associated to the output K1

Po 2

1

15

----

10

power of the compressor associated to the output K2

Po 3

1

15

----

10

power of the compressor associated to the output K3

Po 4

1

15

----

10

power of the compressor associated to the output K4

Po 5

1

15

----

----

power of the compressor associated to the output K5

Po 6

1

15

----

----

power of the compressor associated to the output K6

Po 7

1

15

----

----

power of the compressor associated to the output K7

Po 8

1

15

----

----

power of the compressor associated to the output K8

LABEL MIN.

MAX.

U.M.

DEF.

USER RUNNING WORKING HOURS COUNTER

t r1

----

----

hour

----

running working hours of the user associated to the output K1

t r2

----

----

hour

----

running working hours of the user associated to the output K2

t r3

----

----

hour

----

running working hours of the user associated to the output K3

t r4

----

----

hour

----

running working hours of the user associated to the output K4

t r5

----

----

hour

----

running working hours of the user associated to the output K5

t r6

----

----

hour

----

running working hours of the user associated to the output K6

t r7

----

----

hour

----

running working hours of the user associated to the output K7

t r8

----

----

hour

----

running working hours of the user associated to the output K8

LABEL MIN.

MAX.

U.M.

DEF.

ALARM CODES READING

AlAr

----

----

----

----

alarms code reading

LABEL MIN.

MAX.

U.M.

DEF.

PROBES READING

Pb r

----

----

(3)

----

suction probe reading

Pb F

----

----

(4)

----

condensing probe reading (5)

LABEL MIN.

MAX.

U.M.

DEF.

ANALOG OUTPUT READING

outF

0

100

%

----

analog output reading (5)

LABEL MIN.

MAX.

U.M.

DEF.

CONDENSER FANS REGULATOR

F 1

F 6

F 7

(4)

12.00 condenser fans activation setpoint (5)

Notes
• the symbol (1) indicates that the parameter is available both to the first and to the second level
• the symbol (2) indicates that the parameter is available to the first level only
• the symbol (3) indicates that the unit of measure depends from the parameter /5P and from the parameters /A6 and /A7 (the parameters /

5P, /A6 and /A7 belong to the User Menu; see the chapter User Menu on the page 32)

CONFIGURATION PARAMETERS AND DEFAULT VALUES SUMMARIZING TABLE

Operator Menu configuration parameters