OPERATOR MENU

Configuration parameters setting - Operator Menu configuration parameters

CONFIGURATION PARAMETERS SETTING
Operator Menu configuration parameters are arranged on two lev-
els, to protect the most tricky settings against undesirable violations and
they are arranged in families that can be recognized through the initial
letter of the label.
To gain access to the first level:

a) repeat the passage b of the chapter Configurator Menu on

the page 25.

To select a parameter of the first level:

b) repeat the passage c of the chapter Configurator Menu on

the page 25.

To display the parameter value:

c) repeat the passages d and e of the chapter Configurator

Menu on the page 25.

To gain access of the second level:

d) repeat the passage c of the chapter Configurator Menu on

the page 25 as long as the instrument displays the label OPEr

e) repeat the passage g of the chapter Configurator Menu on

the page 25.

f) push and release over and over the up or the down key as

long as the instrument displays the value established with the
parameter PPP (keeping pushed the up or the down key the
value gets increased or decreased more quickly: the param-
eter PPP belongs to the Operator Menu and it establishes the
Operator Menu password, normally it is -19; see the chapter
User Menu on the page 32)

g) after the modification push and release the set key (to the

release of the set key the instrument displays St 1, the label of
the first parameter of the second level).

To select a parameter of the second level:

h) repeat the passage c of the chapter Configurator Menu on

the page 25 as long as the instrument displays the label of the
desired parameter.

To modify the parameter value:

i)

repeat the passages k, l and m of the chapter Configurator
Menu
on the page 25.

To turn out from the Operator Menu configuration parameters setting
procedure:

j) keep pushed for two seconds at least the menu key or the ON

STAND-BY key.

Additional informations
• during a corrupted memory data alarm the access to the

Operator Menu configuration parameters setting procedure
is refused (see the paragraph Alarms on the page 46)

• the parameters value gets stored in a non volatile memory

even if a lack of power supply happens.

OPERATOR MENU CONFIGURATION PARAMETERS
To make easy the configuration parameters consultation of this Menu,
we have provided to divided it in families.

LABEL MIN.

MAX.

U.M.

USERS STATUS

St 1

OFF

On

----

status of the user associated to the
output K1

St 2

OFF

On

----

status of the user associated to the
output K2

St 3

OFF

On

----

status of the user associated to the
output K3

St 4

OFF

On

----

status of the user associated to the
output K4

St 5

OFF

On

----

status of the user associated to the
output K5

St 6

OFF

On

----

status of the user associated to the
output K6

St 7

OFF

On

----

status of the user associated to the
output K7

St 8

OFF

On

----

status of the user associated to the
output K8

Notes
• to load/unload manually the power steps see the paragraph

Manual power steps loading/unloading on the page 11.

St 1

status of the user associated to the output K1

If the parameter tyP1 has value FAn, it permits to display the status of
the condenser fans associated to the output K1.
If the parameter tyP1 has value CP or Cho, it permits to display the
status of the power step associated to the output K1.