33

RS232 cable

RS232/RS485

RS485

PC

Converter Plug AC100 / AC100 Plus

Comm Opt

u

4

RS232 Yes

4RS485 Yes

Note

When RS485 func-

tion is enabled, the

Ethernet will be

disabled.

Note

The RS232/ 485

converter is an op-

tional component.

Comm Opt

u

4

RS232 Yes

4RS485 Yes

Note

When the RS485

function is ena-

bled, the Ethernet

will be disabled.

RX+

RX-

RS485 Single Connection

1. Setup of RS485

Access Menu, select “Options” > “Comm. Opt”
> “RS485”, select “Yes” to enable RS485
function.

2. Turn off the reader.
3. Plug the RS485 cable extender to the connector. Connect another

end of the cable to the RS232/485 data converter.

4. Connect the RS485 data converter to the RS232 port of PC.
5. Turn the power on.

RS485 Network Connection

1. Setup of RS485

Access Menu, select “Options” > “Comm. Opt”

> “RS485”, select “Yes” to enable RS485
function.

2. Turn off the reader.
3. Plug the RS485 cable extender to the RS232/485 port on the Power Controller, and an-

other end of the cable to the RS232/485 network.