Dead Band

Point at which brakes

start taking effect

Throttle neutral position

Position at which

motor star ts to
run

100

50

0

%

Brake (Reverse) operation

Br
aking f

orce

Re
v

erse P

o

w

e

r

100

50

0

Forward operation

Throttle response

FWB "50"

FWB "0"

107

Fu
n

c

tio

n

ESC Link Function "MCLNK"

DBA-(DEAD BAND) ±2μs~±50μs

Same as Link software Dead Band.

This sets the range (neutral point range) over which
the ESC does not respond to transmitter throttle op-
eration.

The larger the set value, the wider this range.

LBP-(LOW BATTERY VOLT) 2.5V~6V

Same as Link software Low Bat Protection

This setting cuts off the output to the motor when the
running battery voltage drops to the set voltage to
prevent the receiver from stopping operation when
the supply of voltage to the receiver becomes insuffi
cient while running due to a drop of the power sup-
ply voltage. When the power supply voltage recov-
ers, power is supplied to the motor once more.

CTM-(C.L. TIME LIMIT) 50A~300A /CLT-(C.L. TIMER) 0sec(OFF)~240sec

Same as Link software Current Limiter (Time Limit)/Current Limit timer.

The output current can be limited up to the set time lapse from the start of running. This is effective in prevent-
ing the motor from outputting wasted energy when the voltage is high immediately after the power battery was
recharged.

- "CTM" (Time Limit) sets the maximum output current within the time the output current is limited.

- "CTM" sets the time the output current is limited. This function is disabled when set to "0" sec.

Since the Current Limit Timer starts when the throttle is operated to the forward side and current is output to
the motor, this function begins to operate when the motor is run during trim adjustment, etc.

nTB-(NEUTRAL BRAKE) 0%(OFF)~100%

Same as Link software Neutral Brake.

Make this setting when you want to use the brakes at the neutral throttle (OFF)
position by throttle operation. The larger this value, the greater the braking
force. When you want to use the neutral brake, set this value to "0%".

BMD-(BRAKE MAX DUTY) 0%~100%

Same as Link software Brake Max. Duty.

This setting can set the braking force between the neutral point and
Max brake point. The larger this value, the greater the braking force.
When set to "0%", the brakes are not effective.

RMD-(REVERSE MAX DUTY) MC401CR w/back only 0%~100%

Same as Link software Reverse Max. Duty

This setting can set the reverse power between the neutral point
and Max reverse point. The larger this value, the greater the reverse
power. When set to "0%", the reverses are not effective.

FWB-(FORWARD BOOST) MC401CR/MC601C only

Same as Link software Forward Boost

O p e r a t i o n n e a r t h e
throttle tr igger (stick)
neutral position becomes
a sharp rise.