7

S00201 Keypad Selections
(left to right on keypad screen) Example:



Default Name

Selections

Description

0

User Logon
Mode

0 = Standard user ID logon or Card Number logon:
1 = 4 digit, 2 = 5 digit, 3 = 6 digit, 4 = 7 digit, 5 = 8
digit
6 = 9 digit, 7 = 10 digit

Users can enter their card # at LCD
keypad & keypad readers.

0

Service Pin Mode

0: Permanent
1: Temporary
2 = 6 Digit Pin of the day

“6 digit pin of the day” service PIN mode

related to: “Dealer ID” S002:04

. Contact

the Central Monitoring facility and provide
them with this number to obtain the required
PIN for the current day. While in this mode,
any manually configured service PIN will be
ignored.

0

Escort Required
Mode

0 = escorted by users with Escort authority.
1 = escorted by Permanent Users.
2 = escorted by a Permanent or Temporary user.

Escort type a Visitor is accompanied by.

(no)

5 Digit PIN

(yes)

(no)

Whether or not user PIN entry will
require 5 digits.

(yes)

PIN Duress

(yes)

(no)

Refers to users reversing the last 2
digits when entering their PIN at a
keypad to indicate they are being forced
to enter (or forced to login at a keypad).
Note: Applicable reader(s) must be set
for "Card and/or PIN" entry.

(UK ACPO =  no)

(no)

Access Panic
Tokens

NOTE: This feature is
only available with the
addition of the Feature
Expansion Board.

(yes)

(no)

(no)

Blind Card
Re-enrollment

NOTE: This feature is
only available with the
addition of the Feature
Expansion Board.

(yes)

(no)

Meaningful only if using card enabling
feature

(yes) Supports

Intrusion

(yes)

(no)

System Type. Viewing only.
Dependent on setting in Director
Software.

(yes)

Supports Access

NOTE: This feature is
only available with the
addition of the Feature
Expansion Board.

(yes)

(no)

System Type. Viewing only.
Dependent on setting in Director
Software.

(yes) Supports Central

Station

(yes)

(no)

System Type. Viewing only.
Dependent on setting in Director
Software.

(no)

Supports: Suite
Security Modules

NOTE: This feature is
only available with the
addition of the Director
Software and Feature
Expansion Board.

(yes)

(no)

System Type. Viewing only.
Dependent on setting in Director
Software.

(no)

Supports:
Elevators

NOTE: This feature is
only available with the
addition of the Director
Software and Feature
Expansion Board.

(yes)

(no)

System Type. Viewing only.
Dependent on setting in Director
Software.

0

·

0

·

0

·



·

Save S002

01