Advanced Program Sections, Sub Program Sections and Selections

NOTE: For quick reference to locate Advanced Programming Section Selections, consult the Index at the back of this
manual.

WARNING: Access, Elevator and Suite Security selections are only available with the addition of the
“Feature Expansion Board” to the System.

Programming selections whose boxes are grey are not available for this version.

System Global Timer Delay Codes

00: undefined;
01: 1 sec;
02: 2 sec;
03: 3 sec;

04: 5 sec;
05: 10 sec;
06: 15 sec;
07: 20 sec;

08: 30 sec;
09: 45 sec;
10: 60 sec;
11: 90 sec;

12: 2 min;
13: 3 min;
14: 5 min;
15: 10 min;

16: 15 min;
17: 20 min;
18: 30 min;
19: 45 min;

20: 60 min;
21: 90 min;
22: 2 hr;
23: 4 hr;

24: 6 hr;
25: 8 hr;
26: 10 hr;
27: 12 hr;

28: 16 hr;
29: 20 hr;
30: 1 day;
31: 1 week

Program Section: S001 (System Wide Selections)

S00100 Keypad Selections
(left to right on keypad screen) Example:


Default Name

Selections

Description

14
(5 min)

Burglary Siren Time

Siren Time: See Timer Delay Codes Chart 00 =
disabled to 22 = 2 hrs max.

How long a siren in the system will
sound.

(UK ACPO = 16: 15 min)
(European = 17: 20 min)

03

Number of panel
inputs

Multiply entries by four (4)
E.g. 4 X 1 = 4. Enter “1” for 4 inputs.
4 X 2 = 8. Enter “2” for 8 inputs.
4 X 3 = 12. Enter “3” for 12 inputs.
4 X 4 = 16. Enter “4” for 16 inputs.
4 X 5 = 20. Enter “5” for 20 inputs.

MONITOR Panel default = 2

For VBUS input boards connected to the
main controller VBUS port. 20 inputs
maximum. 12 on main board and 1
VBUS input boards possible.

01

Number of panel
outputs

Multiply entries by four (4)
E.g. 4 X 1 = 4. Enter “1” for 4 outputs.
4 X 2 = 8. Enter “2” for 8 outputs.
4 X 3 = 12. Enter “3” for 12 outputs.
4 X 4 = 16. Enter “4” for 16 inputs.
4 X 5 = 20. Enter “5” for 20 inputs.
4 X 6 = 24. Enter “6” for 24 inputs.
4 X 7 = 28. Enter 7” for 28 inputs.

MONITOR Panel default = 2
(UK ACPO = 3: 12 outputs)

For VBUS output boards or modem
output boards connected to the main
controller VBUS port. 26 outputs
maximum. Program for 28 outputs and
skip outputs 27 – 28. 2 relays on main
board and 2 VBUS output boards
possible or 1 VBUS output board and
one 8 output modem board. Also see
S001:06 -07.

0

Panel Type

0 = Monitor xL, 1 = MONITOR ISM, 2 = Future, 3
= Future.

1

Module Bus

(SNAPP)

Baud Rate

0 = Auto Minimum (19K2), 1 = Auto Maximum
38K4

The communications speed between the
main panel and the expansion modules.

1

Suite Security

(Condo)

Baud Rate

NOTE: This feature is only
available with the addition of
the Director Software and
Feature Expansion Board.

0 = Auto Minimum (19K2), 1 = Auto Maximum
(38K4) 2 = 9600 (Auto Minimum), 3 = future.

The communications speed between the
main panel and the Suite Security
modules.

0

Fallback Users

0: No access; 1: All readable tokens; 2: All with
valid site code; 3: 10 fallback users

Specific Cards granted access if door
controller is unable to access the panel
database.

(UK ACPO = 3)





14

·

03

·

01

·

0

·

1

·

1

·

0