Save s003 – Interlogix Monitor XL Advanced Installation Guide User Manual
Page 15

21-3602E rev1.5
Monitor xL™ Advanced Installation Guide
9
S00203 Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
10
(60sec)
Point Reset
Time
Delay table.
Delay time.
(UK ACPO = 02) (European = 04)
0
Language Set 0=Eng,Fre,Dut,Spa, 1=Eng,Slk,Slk,Slk, 2=Future,
3=Future
0
Remote FW
Down/Up
Load
0 = Allowed, 1= Must be authorized
0
Arming Rules 0 = Normal operation. Entry/Exit keypad standard
tone.
1 = Disarm to off by token. Entry/Exit keypad
standard tone.
2 = Constant keypad Entry/Exit tone
3 = Disarm to off by token. Constant keypad
Entry/Exit tone.
Standard Tone = intermittent
Entry/Exit tone, constant alarm tone.
Constant Tone = constant Entry/Exit
tone, intermittent alarm tone.
Standard keypad tones are
reversed.
S00204 Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
_ _ _ _ _ Keypad Lock Code
Equivalent of RF reader lock code for
new RF keypads only.
S00205 Keypad Selections (left to right on keypad screen)
Default Name
Selections Description
_ _ _ _ _ Dealer ID
0 – 65535
This setting is used with the “6 digit pin of the day” service PIN mode. Contact the
monitoring station and provide them with this number to obtain the required PIN
for the current day. While in this mode, any manually configured service PIN will
be ignored. Related: “Service PIN Mode” is the 2
nd
field under S002:1.
S00300 Primary Card Format—Site Code Checking
WARNING: S003
00
–
S003
05
Access Control related
selections are only available with the addition of
the “Feature Expansion Board”.
Keypad Selections (left to right on keypad screen) Example:
Default Name
Selections
Description
(no)
Check for Site Code
(yes)
□
(no)
Whether or not primary-format tokens must have a
specific site code to be granted entry.
06
Site Code Position
1 – 40
The position of the 1st digit for the site/system code on
these access tokens.
Position value changes depending on site code length.
10
Site Code Length
1 – 16
The length of the site code for primary-format tokens
(number of digits).
Site code when represented as a digital #. Can not
exceed 4 digits.
S00301 Primary Card Format—Site Codes
Keypad Selections (left to right on keypad screen)
Default Name
Selections
Description
0000
1st Site Code Value
0000 – 9999
The 1st of up to three site/system codes that can be encoded within
access tokens to be used at the site.
0000
2nd Site Code Value
0000 – 9999
The 2nd of up to three site/system codes that can be encoded
within the access tokens to be used at the site.
0000
3rd Site Code Value
0000 – 9999
The 3rd of up to three site/system codes that can be encoded
within the access tokens to be used at the site.
If site code checking is enabled for the primary card/token format cards encoded with any one of up to three site code values can be used at the
site. (All other cards will be globally denied access.)
·
06
·
10
···········
Save S003
00