Save s001 – Interlogix Monitor XL Advanced Installation Guide User Manual

Page 9

Advertising
background image

21-3602E rev1.5

Monitor xL™ Advanced Installation Guide

3

S00101 Keypad Selections (left to right on keypad screen)
Default Name

Selections

WELCOME
(16 available
characters)

Main screen
message

A greeting message that rotates with any other main screen messages. It can be customized
with the cursor under a letter or in a blank space and pressing the desired keypad button to
enter a particular letter/number. Use the left and right arrow keys to maneuver back and forth.
Use the underscore key “ _ “ on the keypad to insert a space or clear a character.

(UK ACPO = CHUBB SECURITY)


S001
02 Keypad Selections
(left to right on keypad screen) Example:



Default Name

Selections

Description

000000 Panel Unique ID

(Panel Code, System ID)

A (non-zero) number to identify the
panel, site, or account to the Director
software. For an existing system to be
synchronized with the Director software,
this must be a non-zero value set here
to match the "Panel Code" in the
software.

(no)

Unlock Doors on Fire
Alarm

NOTE: This feature is only
available with the addition of the
Feature Expansion Board.

= Global Unlock

(no)

Will a fire alarm unlock all controlled
doors in the facility?

(no)

Auto Update Card
Version

NOTE: This feature is only
available with the addition of the
Feature Expansion Board.

Allow automatic version update.

Disable update

Whether or not replacement cards are to
be granted entry, and the system is to
be updated with the higher version
number automatically. (This setting
refers to fixed-ID cards with a version
number).

(no)

Delay Screen

(yes)

(no)

(UK ACPO = yes)

(no) Fast Restore

(yes)

(no)

If a point restore is to be sent within 1

min. (as opposed to siren time-out).
UK ver. is 12 sec

.

(UK ACPO = yes)

(no) Ring Back Required

(yes)

(no)

If monitoring station will cause keypad
tone & siren to confirm area arming (for
UL).

(no)

Suite Secuirty System

NOTE: This feature is only
available with the addition of the
Director Software and Feature
Expansion Board.

0 = Normal, 1 = Different users per area.

(no) Single Panel

(yes)

(no)

Yes = Single Panel
No = Multi Panel connection.

(no)

Enable Wall Tamper

(yes)

(no)

Main control box back tamper.

(UK ACPO = yes)


S001
03 Keypad Selections (left to right on keypad screen)
Default Name

Selections

Description

000000 3

rd

Party

Password

This is a security ‘key’ that blocks an unauthorized connection to this panel
i.e., by a PC running another copy of the Director software.

000000

·



Save S001

02

Advertising