Save r001 – Interlogix Monitor XL Advanced Installation Guide User Manual

Page 61

Advertising
background image

21-3602E rev1.5

Monitor xL™ Advanced Installation Guide

55

R00110 Keypad Selections
(left to right on keypad screen) Example:


Default Name

Selections

Description

000

Unlock Mode
Schedule

000 = Treat as In Window setting
001 – 050 (Schedule)

Enter a schedule for automated door
unlocking.

0

Unlock In Schedule

0=Lock, 1=Unlock, 2=Pending First
User, 3=Area is OFF, 4=Area Stay/OFF

The unlock mode for while the schedule
is active (or 24 hrs).

0

Unlock Out of
Schedule

0=Lock, 1=Unlock, 2=Pending First
User, 3=Area is OFF, 4=Area Stay/OFF

The unlock mode for after-hours (outside
of the sched.)

1

Arming Level

0=Not legal, 1= Stay/On 2= Future 3= On
only

Select the area arming levels for this
door to be monitored.

2

Token Format

0=none, 1=future (dallas), 2=weigand
3=mag

This is the type of tokens and
readers assoc. with this door.

(no) Detect Wandering

Patient

(yes)

(no)

Enable wandering patient(s)
detection.

(no)

Lock On Wandering
Patient

(yes)

(no)

This allows having the door lock when a
wandering patient is detected.

(no)

In/Out Station

(yes)

(no)

For a reader used to log personnel
entries & exits only. This refers to a 'time-
clock' or 'In/Out Status' application for a
reader that is typically NOT wired to a
door lock.

R00111 Keypad Selections (left to right on keypad screen)
Default Name

Selections

Description

(no)

Interlock Required

(yes)

(no)

A second interlock door can not be
opened until the interlock door that
was first opened is closed.

01

Interlocked Door 1

2 Digits 00 – 32 00 - No interlock 1-32
(Door Number)

01

Interlocked Door 2

2 Digits 00 – 32 00 - No interlock 1-32
(Door Number)

01

Interlocked Door 3

2 Digits 00 – 32 00 - No interlock 1-32
(Door Number)

06

Interlock Delay

00-31 (Delay Table) 06 = 15 Sec

R00112 Keypad Selections Held Open Door Processing (left to right on keypad screen)
Default Name

Selections

Description

(no)

Held Open Processing
Transmit Off

(yes)

(no)

(no)

Held Open Processing
Transmit Stay

(yes)

(no)

(no)

Held Open Processing
Transmit On

(yes)

(no)

(no)

Held Open Processing
Siren Off

(yes)

(no)

(no)

Held Open Processing
Siren Stay

(yes)

(no)

(no)

Held Open Processing
Siren On

(yes)

(no)

(yes)

Held Open Processing
Alert Off

(yes)

(no)

(yes)

Held Open Processing
Alert Stay

(yes)

(no)

(yes)

Held Open Processing
Alert On

(yes)

(no)

000

·

0

·

0

·

1

·

2

·



·

Save R001

10

Advertising